MX-2100/2104
Installation and Operation Manual
Appendix B Alarms
Configuration Error
Messages
B-13
ERROR 26
MODULE TYPE MISMATCH BETWEEN DATABASE AND HARDWARE
The module type recorded in the MX-2100 data base differs from the module
sensed by the MX-2100.
ERROR 27
ILLEGAL CLOCK SELECTION FOR MODULE TYPE
The selected timing mode is not supported by the module whose number has
been specified in the command.
ERROR 28
ILLEGAL COMMAND FOR INSTALLED MODULE
The command you have entered is not supported by the module whose number
has been specified in the command.
ERROR 30
ILLEGAL DCD_DEL AND INTERFACE COMBINATION
The DCD_DEL parameter is not supported by the selected supervisory port
interface (the DCD DEL parameter must be 0 when the supervisory port interface
is DCE).
ERROR 31
ILLEGAL COMMAND, DOWNLOAD NOT SUPPORTED
The command you have entered cannot be executed when downloading is
disabled.
ERROR 32
ILLEGAL PROTOCOL AND TIMING COMBINATION
You are trying to select a channel timing mode for a data channel configured for
asynchronous operation.
ERROR 33
REDUNDANT ML NOT INSTALLED
No redundant KML module is installed.
ERROR 34
DISCONNECT LOOP BEFORE CONFIGURATION CHANGE
You are trying to change the configuration while a loop is activate this is not
allowed.
ERROR 35
ILLEGAL TIME DIVISION DEFINITION (
<
day>)
The periods defined by means of the DEF AGENDA commands are not correctly
sequenced.
ERROR 36
ILLEGAL DATA BASE FLIP TIME
You must define two valid data base flip times.
ERROR 37
CONFLICT IN INTERFACE AND DSR PARAMETER
You are trying to select DSR=ON after the supervisory port interface has been set to
DTE.
ERROR 38
ILLEGAL COMMAND, ALTERNATE DATA BASE IS ACTIVE
The command entered by you is not supported on the alternate data base (only
DEF commands are supported).