Appendix B Alarms
MX-2100/2104
Installation and Operation Manual
B-14
Configuration Error
Messages
ERROR 39
ILLEGAL COMMAND FOR CURRENT SYSTEM TYPE
The command entered by you is not supported by the MX-2104.
ERROR 41
ILLEGAL COMMAND NO CONNECTED CHANNELS
You are trying to enter a command that is supported only when the channel
specified in the command is connected.
ERROR 42
CONFLICT IN FRAME MODE AND DOWNLOAD
You can select manual frame bit allocation only when downloading is disabled.
ERROR 43
ILLEGAL FRAME ALLOCATION
An incorrect bit allocation has been detected, i.e., the same bits have been
assigned to different channels, or the specified start or end bit number is invalid.
ERROR 44
ILLEGAL LINK CLOCK AND ML MODE COMBINATION
You can select the main link clock source only when using the dual-link or priority
bumping mode, provided a KDI module is installed in the MX-2100.
ERROR 45
ILLEGAL LINK CLOCK AND ML TIMING COMBINATION
When selecting one main link as the clock source, the timing mode of the other
main link cannot be DTE or LBT.
If both main links use LBT or DTE timing, the LINK_CLK parameter must be set to
NONE.
ERROR 50
ILLEGAL COMBINATION OF INTERFACE AND ECHO CANCELLER
You are trying to disable the echo canceller of a voice module, e.g., KVC.2, etc.,
when its interface is 2-WIRE. This is not allowable, because when the link
connecting between the subscribers includes hybrids, the quality of transmission
without echo cancellers is degraded.
ERROR 51
ML_MODE AND HARDWARE CONFIGURATION CONFLICT
The MX-2100 is equipped with only one KML module, but you are trying to select
a main link mode that requires two KML modules (i.e., only the SINGLE mode is
allowed).
ERROR 52
CONFLICT BETWEEN CH1 AND CH2 SPEEDS
•
You are trying to configure channels 1 and 2 of a KLS.1 module to operate
with data rates from different groups. This is not allowed.
•
For the KVF.4/S0 module, you cannot select a 64 kbps rate for both the B1
and B2 channel.
ERROR 56
ILLEGAL START TIME SLOT ALLOCATION
You are selecting an incorrect starting time slot on the KVF.5 master module.
ERROR 58
ILLEGAL SIGNALING MODE
You are selecting an incorrect signaling parameter in KVF.5 or KVF.6 modules.