Appendix B Alarms
MX-2100/2104
Installation and Operation Manual
B-16
Configuration Error
Messages
ERROR 209
CHANNEL SOURCE OF MASTER/FALLBACK CLOCK DOES NOT EXIST
You are trying to select a channel that is not physically present as the clock source.
ERROR 210
INVALID ML-B CARD TYPE FOR SWITCH BACKUP ML MODE
You can select the switched backed mode only when a KML.1, KML.2, KML.3 or
KML.10 module is installed.
ERROR 211
ML MODE NOT COMPATIBLE WITH NO. OF ML
Before selecting the dual-link or priority bumping mode, make sure to configure
two links.
ERROR 212
CONNECTED MUXES SHOULD HAVE THE SAME NO. OF
CONFIGURATIONS
For two MX-2100 connected in a link, always define the same number of data
bases (either one or two data bases on each unit).
ERROR 213
KM2104 CAN HAVE ONLY ONE LINK
You are trying to define a second link on a MX-2104. This is not supported.
ERROR 214
LOCAL-REM SLOTS OP. HIGHWAY OR ML PRIORITIES,
INCOMPATIBLE
Check configuration of main link priorities for all the modules.
ERROR 215
KM2104 OFFSET, EDIT-AGENT MISMATCH
The current offset and the offset in the edited data base are different.
ERROR 218
ONLY ONE KDI/KDI.CH IS ALLOWED IN A MUX
Only one KDI or KDI/CH can be installed (or programmed) in a MX-2100.
ERROR 226
ML BITWEIGHT MISMATCH
When performing manual frame allocation, the two MX-2100 connected in a link
must have equal bandwidth allocation units (refer to the
General Information
chapter).
ERROR 234
KVF.5 SLAVE CARDS MUST HAVE A MASTER
Make sure a KVF.5/T1/M or KVF.5/E1/M module is installed.
ERROR 235
TOO MANY KVF.5 CARDS IN THE MUX
The total number of KVF.5 modules inserted in the MX-2100 exceeds the
maximum number needed to process the T1 or E1 signal.
ERROR 236
INVALID KVF.5 TS GROUP
You are trying to select an incorrect group of time slots on a KVF.5 slave module.