MX-2100/2104
Installation and Operation Manual
Appendix E Configuration Parameters
General
E-3
Table E-1. System Parameters (Cont.)
Designation Function
Values
ACTIVE_ML
When redundancy is enabled,
allows the selection of the active
KML module
AUTO
- Automatic selection of active module
ML-A
- Module KML-A is selected
(redundancy switching is overridden)
ML-B
- Module KML-B is selected
(redundancy switching is overridden)
Default: AUTO.
In this case, upon power-up,
the KML-A module is selected as default if
both KML modules are installed and operating
normally
Main Link Configuration Parameters
The following table lists the available main link parameters that can be configured
from the front panel, and their functions. The table also lists the parameter values
included in the MX-2100 default configuration.
The available parameters depend on the type of main link module installed in the
MX-2100 enclosure (for a complete description of all the configuration parameters
of main link modules, including the parameters that can be configured only
through the supervision port, refer to the corresponding main link module
Installation and Operation manual).
Note that when two main link modules of the same type are installed in the
MX-2100 enclosure, the selected parameter values are used by both KML
modules; parameters used by modules serving only for backup may differ.