MX-2100/2104
Installation and Operation Manual
Appendix F Command Set Description
Commands
F-39
The fields appearing on the data form are as follows:
•
SLOT
- Displays the slot in which each module of the group is installed.
•
CARD TYPE
- Displays the module type installed in the corresponding slot:
KVF5/T1/M or KVF5/T1/S for KVF.5 modules for T1, KVF5/E1/M or KVF5/E1/S
for KVF.5 modules for E1 interface.
•
TS_GROUP
- Group of time slots served by the module installed in the
corresponding slot.
•
FROM_PBX
- Signaling to be transferred through the MX-2100s.
•
TO_PBX
- Signaling to be transmitted to the PBX.
•
CCS
- If the selected signaling mode is CCS (from and to PBX), then this field
will indicate which time slot will carry the CCS information.
•
ABCD
- If the selected signaling mode is CAS (any bits selected except CCS),
then the default A,B,C,D to be transmitted to the PBX is displayed in this field.
•
POLARITY
- Polarity of a bit, Normal/Inverted (for master module only).
For the slave modules, displays N/A.
•
EXIST
- Indicates whether the module includes a sub interface.
DSP KVF6
Purpose
Display the configuration parameters of the KVF.6 modules in the MX-2100.
Format
DSP KVF6
Use
•
Type:
DSP KVF6 <ENTER>
Typical data for E1/T1 cards is shown as follows:
IO SLOT CARD_TYPE FRAME SIG_MODE TS A B C D EXIST
3 KVF6/T1/24 SF(D4) CAS N/A A B N/A N/A YES
6 KVF6/E1/16 G.732S CAS N/A A B A B NO
7 KVF6/T1/12 ESF CAS N/A A OT_A O 1 YES
8 KVF6/E1/31 G.732N CAS 5 N/A N/A N/A N/A YES
The fields appearing on the data form are as follows:
•
SLOT
- Displays the slot in which each module of KVF.6 is installed.
•
CARD_TYPE
- Displays the module type installed in the corresponding slot:
KVF.6/T1/24, KVF.6/T1/12, KVF.6/E1/31, or KVF.6/E1/16.