Appendix F Command Set Description
MX-2100/2104
Installation and Operation Manual
F-42
Commands
CARD TYPE
SOFTWARE REV.
HARDWARE REV
SLOT 3 ML
XX.YY
XX.YY
SLOT 4
XX.YY
XX.YY
SLOT 5
XX.YY
XX.YY
SLOT OPTIONS
XX.YY
XX.YY
SLOT 1
XX.YY
XX.YY
SLOT 2
XX.YY
XX.YY
.
XX.YY
XX.YY
.
XX.YY
XX.YY
SLOT 12
XX.YY
XX.YY
2. To display the information related to a specific module, type:
DSP REV i <ENTER>
where i is the number of the MX-2100 slot of the desired module
(3, 4, 5, OP, and I/O slots 1 through 12).
DSP ST FRAME
Purpose
Display information on the frame structure and the use of the available main link
bandwidth. Refer to the
General Information
chapter for additional information.
Format
DSP ST FRAME {A B}
or
DSP ST FR {A B}
Use
1. To display frame information for main link A, type:
DSP ST FRAME A <ENTER>
or
DSP ST FR A<R>
If MX-2100 is equipped with only one main link module, it is not necessary to
identify the main link.
2. To display frame information for main link B, type:
DSP ST FRAME B <ENTER>
or
DSP ST FR B<R>
Display Format - AUTO Frame Bit Allocation
A typical DSP ST FRAME display when the frame bit allocation mode (selected by
means of the
DEF SYS
command) is automatic is shown below:
FRAME LENGTH
= XXX BIT (XXX KBPS)
BIT WEIGHT
= XXX KBPS
DATA USAGE
= XXX KBPS
CONTROL USAGE
= XXX KBPS
DOWNLOAD USAGE
= XXX KBPS
SYNC USAGE
= XXX KBPS
TOTAL USAGE
= XXX KBPS
TOTAL FREE
= XXX KBPS