MX-2100/2104
Installation and Operation Manual
Chapter 1 General Information
Technical System Characteristics
1-51
Control Signals
RS-232 & V.35
Full local support of all control signals
V.36
Full local support of all control signals, with
the exception of RI
X.21
Local support of C and I
Clock Modes
KML.1, KML.2, KML.3,
KML.4
DTE, External DCE and DCE
KML.5, KML.6
Internal and Loopback
KML.7, KML.8, KML.F
Internal, Loopback and DCE
KML.10
DTE
Equipment
Enclosure
MX-2100 MX-2104
Physical Description
18 slot card cage
4 slot card cage
Slot Use
2 power supply slots
2 main link slots
1 common logic slot
1 optional slot
12 I/O slots
Built-in power supply
Built-in main link
Built-in common logic
0 optional slots
4 I/O slots
Dimensions
19” rack mount, front-mounting or standalone
unit
Height
13.26 cm/5.22 in
(3U)
4.4 cm/1.75 in
(1U)
Width
43.7 cm/17.20 in
43.0 cm/17.30 in
Depth
25.25 cm/9.94 in
25.4 cm/10 in
Power Requirements
Supply Voltages
100 to 240 VAC
(
±
10%), 50/60 Hz
-24 VDC or -48 VDC
100 to 240 VAC
(
±
10%), 50/60 Hz
-48 VDC
Power Consumption
30 VA, 50 VA
20 VA max
Environment
Operating Temperature
32 to 104
°
F (0 to +40
°
C)
Storage Temperature
0 to 160
°
F (-20 to -70
°
C)
Humidity
Up to 90%, non-condensing