Chapter 2 Installation
MX-2100/2104
Installation and Operation Manual
2-6
Site Requirements and Prerequisites
Current and Power Capabilities of MX-2100 Power Supply Modules
The following table lists the power that can be provided by the individual
MX-2100 power supply modules when cooled by free air connection.
Table 2-2. Nominal Power Consumption of Power Supply Modules
Module
+5V Output
+12V Output
-12V Output
Maximum
Total Power
Per Module
Power [W]
Power [W]
Power [W]
[W]
KPS.3, KPS.5
15.5
4.8
4.8
25
KPS.4 30 12 9.6
50
KPS.6 55 10.2
10.2
56
KPS.7 55 10.2
10.2
56
MX-2104/AC 30
7.2
7.2
30
MX-2104/48 40
7.2
7.2 40
•
Power supply modules of the MX-2100 have load-sharing capabilities. By
installing two KPS modules it is possible to double the allowed loading.
If the power requirements exceed the capabilities of a single power supply
module, you cannot consider that the two modules are providing redundancy.
Any failure must be immediately corrected.
•
KPS.4
The nominal output power specified for the KPS.4 module can be safely
exceeded to the following maximum output power:
+5V 40W
+12V 18W
–12V 12W
The total power supplied by the module CANNOT exceed the Maximum Total
Power Per Supply of 50W.
•
KPS.6, KPS.7
The +5V output must always be loaded.
The minimum current consumption from the +5V output is 3A (15W). If a lower
current is needed, use a power supply module with lower output currents.
With forced air cooling, the Maximum Total Power of the module can reach up
to 80W.