Chapter 2 Installation
MX-2100/2104
Installation and Operation Manual
2-22
Initial Setup and Configuration
Table 2-9. Typical Terminal Control Sequences
Function Terminal
Type
TV920 VT52
VT100 Freedom
100/110
Freedom
220
Clear Screen
1B2A0000
N/A
1B5B324A
1B2A0000
1B5B324A
Cursor Home 1E000000
1B480000
1B5B4800
1E000000
1B5B4800
Cursor Right
0C000000
1B430000
1B5B3143
0C000000
1B5B3143
If the MX-2100 system is not yet configured, use the command
DEF SYS
to
define at least one PS module and one KCL.2 module. Refer to the
Command Set
Description
appendix for more information.
Supervisory Port Configuration
After completing the procedure given above, the supervisory port of MX-2100 uses
the default values. If necessary, change the configuration of the SP (supervisory)
port of MX-2100 by entering the command
DEF SP.
Refer to the
Command Set
Description
appendix for more information.
You will see the supervisory port configuration data form. A typical form with the
default values is shown below:
SPEED DATA
PARITY INTERFACE CTS DCD_DEL DSR
9.6 8 NONE DCE
ON
10
ON
POP_ALM PWD LOG_OFF AUXILLARY_DEVICE
NO NO
NO NMS-SLIP
After selecting the required parameters, you may have to change the configuration
of the supervision terminal, to match the new values.
Set the IP address using the
DEF AGENT
command. Refer to the
Command Set
Description
appendix for more information. Then reset by pressing “power on” or
by using the
RESET LOC
command.