Appendix F Command Set Description
MX-2100/2104
Installation and Operation Manual
F-16
Commands
Use
1. Type:
DEF DP <ENTER>
If the KCL.2 module has an Ethernet interface, the following is displayed:
ROUTING_PROTOCOL
NONE
where NONE is the default value.
If the KCL.2 module has RS-232 interfaces, the following is displayed:
SPEED DATA PARITY
CALL_OUT_MODE
9600 8 NONE NO
where the parameter values are the default values.
2. Change the parameter values as follows:
Bring the cursor to the beginning of the first field to be changed by
pressing the space bar.
To change the selected field, press F or B to scroll among the available
selections.
When the desired selection is displayed, press the space bar to move to
the next field.
•
When done, press ENTER.
The second line of parameters is displayed. The following is a typical
display:
LOG_OFF AUXILIARY_DEVICE
ROUTING_PROTOCOL
NO NMS_SLIP
NONE
shows the dial-out parameters and their values.
Table F-2. Dial-out Parameters
Designation
Function
Values
SPEED
Selects the dial-out port data rate.
300, 1200, 2400, 4800, 9600, 19200, 38400 and
57600 bps
DATA
Selects the number of data bits in the
dial-out port word format:
7 or 8 data bits
PARITY
Controls the use of parity.
ODD
- Odd parity
ODD
- Odd parity
EVEN
- Even parity
NO
- Parity disabled (only available with 8 data bits).
CALL_OUT_MODE
Controls the use of the call-out
function:
NO
- Call-out function is disabled.
YES
- MX-2100 will initiate a call after each new
alarm.