Technical Manual
Blind Push Button Smart 55
BE-JTA5504.01
MDT technologies GmbH •
51766 Engelskirchen • Papiermühle 1
Phone: +49-2263-
880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de
29
29
Type of hanging:
Awning
Button assignment
(left / right)
move in / move out
move out / move in
Setting which button is used to
move in which direction
Operating function
Long=In/Out, Short=Stop/Step
Short=In/Out, Long=Stop/Step
Setting the concept of how to
operate with long/short button.
Type of hanging:
Curtain
Button assignment
(left / right)
open / close
close / open
Setting which button is used to
move in which direction
Operating function
Long=open/close, Short=Stop
Short=open/close, Long=Stop
Setting the concept of how to
operate with long/short button.
The following parameters are available for all types of hangings::
Time for long keypress
Basic setting
0,1 s – 30,0 s
Setting of an individual time from
when a long keypress is detected
Group control extra
long
not active
active
Activation of another function on
extra long keypress
Time for extra long
keypress
0,1 s – 30,0 s
[2,0 s]
Setting of an individual time from
when an extra long keypress is
detected
Table 17: Basic Settings – Function Buttons 1/2
Two communication objects appear for the "Blind, Shutter, Awning, Curtain" function. On the one
hand, the movement object for moving the blind ("Up/Down", " Open/Close", "In/Out", according to
the selected hanging), on the other hand, the object for stopping a movement or for sending short
impulses (slat adjustment, fabric tension for awning) ("Stop", "Stop/Step" or "Stop/Slats Open/Close",
according to the selected hangings).
With the setting "
Type of hanging
", the hanging to be controlled can be selected. The appropriate
parameters then appear according to the selection. Among other things, the corresponding symbols
can be used, which are then shown in the display.
Via the
operating function
, it is possible to swap the action for the long and short keystroke. In this
way, it is possible to select whether to move via a long or a short button press. The stop/step object
then adopts the other operating concept.