Description

The GSV-1 is a precise bridge amplifier with an analog output for strain gage full bridges.

The special feature of the GSV-1 is the automatic zero balancing within just 90 
milliseconds across 100% of the measurement range.
The zero balancing is triggered by means of a control signal from the PLC or with a 
pushbutton. The control levels may be in between 3.5 and 30 volts.

The GSV-1 is available in many housing variants and many options, e.g. threshold value 
sensor, peak value store, amplification selection by means of jumpers, stepless 
amplification adjustment, plug connections etc.

The maximum range for the zero balancing is 100% of the sensitivity range with an output 
signal ±5V at the GSV-1L. The GSV-1L with an output signal 0-10V is the zero balancing 
±50% of the sensitivity range.

With options GSV-1H and GSV-1A the zero balancing accounts for ±100% of the nominal 
sensitivity in every amplification level (2mV/V or 3.5mV/V).
The range for the zero balancing does not get reduced when the amplification is 
increased.
 
The GSV-1 can supply up to 4 parallel-connected weighing cells with 350 ohm bridge 
resistance each and is therefore eminently suitable for applications in weighing 
technology. The option GSV-H can supply for 8 weighing cells with 350 ohm bridge 
resistance.

Die Leiterkarte GSV-1L misst nur 30mm x 40mm x 6,5mm und kann aufgrund der 
Stiftleisten leicht als Aufsatz in größere Leiterplatten integriert werden.

The GSV-1L printed circuit board measures just 30mm x 40mm x 6.5mm and can easily 
be integrated as an add-on in larger PCBs thanks to the the pin strips.

The top hat rail housing GSV-1H for mounting rails according to EN50022 is just 12.5mm 
wide and 114.5mm long. 

The measuring amplifier GSV-1HSW additionally contains two threshold value sensors 
with a relay and a peak value store. The thresholds are set either from front-side spindle 
trimmers or connectable remote potentiometers.

The measuring amplifier GSV-1A has a robust aluminum pressure-cast housing in 
environmental protection rating IP66. There is a light cast-plastic housing GSV-1M in IP66 
available for portable applications. 

For multi-channel applications for stress analysis with strain gages, in addition, we also 
offer affordable 8-channel devices with analog outputs.

4

Instruction Manual

Summary of Contents for GSV-1

Page 1: ...Straingage Bridge Amplifier GSV 1 Version July 09 2007 ME Me systeme GmbH Neuendorftstr 18a Tel 49 3302 559 282 DE 16761Hennigsdorf Fax 49 3302 559 141...

Page 2: ...iagram 10 Pin Configuration 11 Adjustment of Input Sensitivity 11 Layout of Jumpers 12 Dimensions 12 Option EP cConnection of an External Potentiometer 12 Aluminum housing GSV 1A 14 Pin Configuration...

Page 3: ...Strain Gage Measuring Amplifier GSV 1 Instruction Manual 3...

Page 4: ...ply up to 4 parallel connected weighing cells with 350 ohm bridge resistance each and is therefore eminently suitable for applications in weighing technology The option GSV H can supply for 8 weighing...

Page 5: ...ification stages 1x 2x 4x 10x and trimmer 1x 10x 5V 10V 4 20mA 0 20mA GSV 1H amplification switching Option TR stepless amplification setting via trimmer potentiometer HSW Version Top hat rail housing...

Page 6: ...ce optional for GSV 1H 5 6 7 5 47 10V 4 20mA 0 20mA V V Ohm Operating voltage Nominal range Operating range Nominal range GSV 1A GSV 1A 12 0 24 10 5 28 GSV 1L 10 5 16 or 18 28 V V V Current consumptio...

Page 7: ...can be switched 1 2 4 10 times with internal jumpers If the input signal is negative output follows up to 0mA the input signal beyond it remains at 0mA Pin Configuration Pins 1 2 US US Bridge supply...

Page 8: ...t voltage at sensitivity option 2 mV V Output voltage at sensitivity option 3 5 mV V 1 1 5 volts at 2 mV V 5 volts at 3 5 mV V 2 2 5 volts at 1 mV V 10 volts at 2 mV V 5 volts at 1 75 mV V 10 volts at...

Page 9: ...rol signal between 5 volts and 24 volts is fed in In this way the zero point of the force sensor will be balanced and the peak value storage will be reset to zero Through internal jumpers the amplific...

Page 10: ...an be selected Mode A actual value mode Signal sequence Amplification peak value storage The threshold indicator reacts to the actual value The actual value is shown on terminal 6 The peak value is sh...

Page 11: ...d of the supply voltage and the ground of the output signal are connected to terminal 8 Adjustment of Input Sensitivity The input sensitivity can be adapted by displacement of the jumper The input sen...

Page 12: ...he ground 12 Instruction Manual 99 0 22 5 1 2 3 4 5 6 7 8 91 01 11 2 1 31 41 51 6 GSV 1HSW SW 1 SW2 SW 1 SW2 Depth 114 5mm for mounting on carrying rails according to EN50022 On exceeding the threshol...

Page 13: ...tput 0 10V is realised with the amplification level 2 b In the standard design the device is equipped with a Bessel filter 2nd order 250 Hz c The calibration by the manufacturer is carried out either...

Page 14: ...o setting terminal 8 is connected to the voltage supply or a control signal between 5 volts and 24 volts is applied Amplification can be switched 1 2 4 10 times by means of jumpers Pin Configuration T...

Page 15: ...factor Output voltage at sensitivity option 2 mV V Output voltage at sensitivity option 3 5 mV V 1 1 5 volts at 2 mV V 5 volts at 3 5 mV V 2 2 5 volts at 1 mV V 10 volts at 2 mV V 5 volts at 1 75 mV...

Page 16: ...Option 718 plug The measuring amplifier GSV 1A is also supplied with plugs of type type 718 The pin configuration is the same as that of module housing GSV 1M 16 Instruction Manual...

Page 17: ...put are connected to the round plug B pin contacts For zero setting Pin 4 is connected to the voltage supply Pin 1 or a control signal between 5 Volt and 24 Volt is applied Dimensions Pin Configuratio...

Page 18: ...oltage supply 2 UD positive differential input 2 GND ground 3 US positive bridge supply 3 5V stabilized 4 US negative bridge supply GND 4 internally reserved 5 GND ground 5 internally reserved 6 UA an...

Page 19: ......

Page 20: ...en Alle Angaben beschreiben unsere Produkte in allgemeiner Form Sie stellen keine Eigenschaftszusicherung im Sinne des 459 Abs 2 BGB dar und begr nden keine Haftung Made in Germany Copyright 1999 2007...

Reviews: