Page 16
Installation
optoNCDT ILR 1181 / 1182
7
( 27)
144
(5.67)
194
(7.64)
Fig. 4 Offset against zero-edge
The sensor zero-point is located 7 mm behind the outer surface of the front cover or 137 mm before the back
cover outside face respectively. This zero-point has been introduced for constructional design reasons. It can
be compensated with the help of parameter “OF“, see Chap.
7.3.17
.
5.2
Reflector Mounting
The sensor measures the distance to moving and static targets:
- in the range of 0.1 ... 50 m on diffuse surfaces,
- between 50 m and 150 m on reflectors (for example reflector film from 3M, Scotchlite Engineer Grade type
I, series 3290).
It is possible to align the sensor using the measuring laser. When aligning check as follows:
Move the sensor at a very short distance to the reflector (for example < 1 m). The light spot is aligned in
the centre of the reflector.
Move the sensor with the longest range to the reflector. Check the position of the light spot at the reflec-
tor and set it if necessary.
The light spot must always be in the centre of the reflector whatever the position.