Document No 7202-D0001-12
21
Mobile Energy Australia Pty Ltd
39 Dulacca Street, Acacia Ridge QLD 4110 Australia
ABN 98 674 578 946
P: +61 7 3273 6803
E:
sales@mobileenergyaustralia.com.au
www.mobileenergyaustralia.com.au
INSTALLATION - continued
7.
Remote Air Intake Filter Removed for Shipping (Optional).
A label on the unit will indicate if the Air Compressor Filter has been removed for the purpose of
shipping. IT IS IMPORTANT THAT THE FILTER IS FITTED BEFORE THE COMPRESSOR IS
STARTED. The following is the instruction for fitting the filter to the compressor.
1.
Remove the front access panel by pulling out the top of the panel until it is free of the rubber
mounts, lift to free from bottom rubber mounts.
2.
Put the hose clamp over the air hose protruding through the top panel and push the Air Intake
Filter inlet tube into the hose.
3.
Using the 2 off M8 x 30 bolts, flat washers, spring washers and nuts, bolt the Air Intake Filter
into place.
4.
Tighten the hose clamp and refit the front panel.
8.
Supply of After Cooler for Diesel Engine Driven Compressor Unit.
It is important for most air tools, that the air supplied should be free of moisture. High content of
moisture in the air will considerably reduce the reliability and life of the air tool. In applications such as
painting with air guns, the finish can be greatly affected by moisture in the air.
Filters used in the standard filter regulator lubricator units have a limit to what they can handle. It is
suggested in areas of high humidity or in situations where the standard FRL is not able to cope with
the moisture that a MEA AFTERCOOLER (Part Number 7201-B0020) is installed onto the
compressor unit. And a MEA water separator be installed with electric solenoid operated drain valve
part number (See Accessories). The following picture shows the MEA AFTERCOOLER installed onto
a SMAC-D.