59
CLEANING AND STORAGE
---------------------------------------------------------------------------------------------------------------------------------------
Before cleaning the humidifier make sure the power has been turned off and the humidifier is
unplugged from the mains.
Once the humidifier has been used for 50 hours it will automatically stop working as it requires
cleaning. The lights on the LED display will blink every two seconds. All the functions set will
be saved and the buttons on the display will be disabled.
The cleaning of the following four components must be carried out: the ultra-sonic pad, the
water tank, the inside of the base and the calcium carbonate filter. These should be cleaned as
frequently as advised in the instructions below, however they MUST be cleaned every 50 hours
when the LED lights start to blink.
Once the cleaning is complete hold the power button down for three seconds. This will reset
the accumulator to 0 hours.
Press the power button again and the humidifier will run as per before.
ULTRASONIC PAD AND PTC HEATER
•
The ultrasonic pad and PTC heater can be located in the base of the humidifier. The ultrasonic
pad vibrates at high speed in order to turn water into mist. The PTC heater heats up the water
when the warm mist option is chosen.
•
In areas where the water quality is hard, limescale will form on the ultrasonic pad and PTC
heater surface. The ultrasonic pad and PTC heater will need to be cleaned with a cleaning
agent.
•
Add a small amount of cleaning agent onto the ultrasonic pad and PTC heater, leave to soak
in the sink for 10 to 15 minutes.
•
Clean the ultrasonic pad and PTC heater with the small brush provided in the lid of the water
tank until the limescale has disappeared.
•
Rinse the ultrasonic pad and PTC heater in water to remove any residue.
•
Do not clean the ultrasonic pad or PTC heater with metal or any material that could scrape and
cause damage.
•
The ultrasonic pad and PTC heater must be cleaned weekly.