background image

 

11

 

 

MAINTENANCE 

----------------------------------------------------------------------------------------------------------------------------- ----------

 

Always turn off the power and disconnect the main cable before performing maintenance procedures.  

INSPECT ELECTRICAL SYSTEM

 

 

Inspect the electrical cord for damage at regular intervals.  

 

CLEANING THE EXTERIOR 

 

 

Clean the exterior with a soft, dry cloth. If the  device  is extremely dirty, use  a mild cleaning 
agent or wipe the dehumidifier with a slightly damp cloth. Never spray the device with water.

 

 

CLEANING THE FILTER 

When  used  regularly,  the  filter  may  become  clogged  with  dust  and  dirt  particles.  The  filter  must  be 
cleaned a minimum of every two weeks (not doing so could invalidate the units’ warranty). Please use 
the following steps:  

 

Remove the filter.  

 

Clean both sides of the filter with the end of a hoover or soapy water no hotter than 40°C. Rinse 
and dry completely before inserting back into the dehumidifier.

 

 

 

STORAGE 

----------------------------------------------------------------------------------------------------------------------------- ----------

 

If the machine will not be used for a long period of time, take the following steps:  
 

1.  Remove the plug from the socket and empty the water tank. Allow the water tank and the 

dehumidifier to dry completely, this can take a couple of days.  

2.  Clean the filter and store the device in a dust-free location away from direct sunlight, 

preferably covered with a sheet of plastic.  

 

 

 

 

 

 

 

 

Summary of Contents for MeacoDry 25Lm

Page 1: ...y 25Lm Instruction Manual MeacoDry 25Lm Dehumidifier Please read this instruction manual before using the dehumidifier and keep safe for future reference Thank you for choosing Meaco we really appreci...

Page 2: ...r cannot fall and cause injury Keep Out of Water Never operate the unit in pooled or standing water as this may create a risk of injury from electrical shock Do not store or operate outdoors If electr...

Page 3: ...ust be designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by an operating electric heaters operating gas appli...

Page 4: ...minal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the...

Page 5: ...d air from the room in and across a filter and then through an evaporator Here the air is cooled below dew point so that the water vapour of the air forms a condensate on the coils which flows into th...

Page 6: ...ull the unit will switch off Once the water tank has been emptied and placed securely back in the unit it will start to run again as per its previous settings ALARM LIGHT The red LED indicates when th...

Page 7: ...dity level increases above 50 rh the compressor will then come back on and start to collect water again 40 rh Setting the unit to reach a target humidity level of 40 means the unit will run until it r...

Page 8: ...k is full the respective yellow LED on the control panel will indicate the tank needs emptying In order to empty the water tank remove the tank from the unit and empty the water The collected water ca...

Page 9: ...entre and insert the water tank back into the unit Extend the hose to the desired drainage point NOTE The maximum water column height our pump kit handles is 4 metres elevation always depends on the p...

Page 10: ...10 ELECTRIC DIAGRAMS DEHUMIDIFIER ELECTRIC WIRING PUMP CONNECTION WIRING...

Page 11: ...articles The filter must be cleaned a minimum of every two weeks not doing so could invalidate the units warranty Please use the following steps Remove the filter Clean both sides of the filter with t...

Page 12: ...m 35 rh to 90 rh It is suitable for applications residential buildings offices museums archives garages and storage rooms Temperature Range 5 C 32 C Relative Humidity Range 35 90 rh Rated Voltage 230V...

Page 13: ...lly It is recommended to switch off the dehumidifier The ambient air humidity is lower than 35 rh Under this condition the dehumidifier becomes inefficient and little water will be collected The air f...

Page 14: ...Defective control assembly Please contact Meaco The unit does not defrost Defective bypass relay valve Please contact Meaco Defective control assembly Please contact Meaco Defective bypass relay valv...

Page 15: ...ge caused by actions that deviate from those as described in the user s manual or by neglect 6 The warranty does not cover faults caused by dirt or by third party products 7 The warranty does not cove...

Page 16: ...to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and...