TROUBLESHOOTING 

----------------------------------------------------------------------------------------------------------------------------- ----------

 

SYMPTON 

CAUSE 

SOLUTION 

 
 
 

Unit does not operate 

 

There is no power to the unit. 

 

 

Plug in the unit and check the 

power outlet. 

 

 

The ON/OFF button has not 

been pressed. 

 

 

Press the ON/OFF button. 

 
 
 
 
 

Unit does not dehumidify or 

collects little water 

 

Ambient temperature is lower 

than +5°C. 

 

 

Under this condition the 

dehumidifier becomes 

inefficient. It is recommended 
to switch off the dehumidifier. 

 

Ambient temperature exceeds 

32°C. 

 

 

Under this condition the 

compressor is overloaded and 

switches off automatically. It is 

recommended to switch off the 

dehumidifier. 

 

 

The ambient air humidity is 

lower than 35%rh. 

 

Under this condition the 

dehumidifier becomes 

inefficient and little water will 

be collected. 

 

 

The air filter is dirty and 

blocked. 

 

 

The air filter must be cleaned. 

If the air filter is beyond 

cleaning, it must be replaced. 

 

 

Below the relative humidity set 

point. 

 

 

This is normal and is not a 

fault. 

 
 
 
 

The compressor is not on 

 

The dehumidifier has just 

turned on. 

 

 

Wait three minutes for the 

compressor to start up. 

 

The overload protector is 

defective. 

 

 

Please contact Meaco.

 

 
 
 

The fan will not turn on 

 

The machine is in Standby 

Mode. 

 

 

Turn the machine on by using 

the UP and DOWN arrows. 

 

 

The fan is not running. 

 

 

Please contact Meaco. 

 

 

 

Summary of Contents for MeacoDry 25Lm

Page 1: ...y 25Lm Instruction Manual MeacoDry 25Lm Dehumidifier Please read this instruction manual before using the dehumidifier and keep safe for future reference Thank you for choosing Meaco we really appreci...

Page 2: ...r cannot fall and cause injury Keep Out of Water Never operate the unit in pooled or standing water as this may create a risk of injury from electrical shock Do not store or operate outdoors If electr...

Page 3: ...ust be designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by an operating electric heaters operating gas appli...

Page 4: ...minal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the...

Page 5: ...d air from the room in and across a filter and then through an evaporator Here the air is cooled below dew point so that the water vapour of the air forms a condensate on the coils which flows into th...

Page 6: ...ull the unit will switch off Once the water tank has been emptied and placed securely back in the unit it will start to run again as per its previous settings ALARM LIGHT The red LED indicates when th...

Page 7: ...dity level increases above 50 rh the compressor will then come back on and start to collect water again 40 rh Setting the unit to reach a target humidity level of 40 means the unit will run until it r...

Page 8: ...k is full the respective yellow LED on the control panel will indicate the tank needs emptying In order to empty the water tank remove the tank from the unit and empty the water The collected water ca...

Page 9: ...entre and insert the water tank back into the unit Extend the hose to the desired drainage point NOTE The maximum water column height our pump kit handles is 4 metres elevation always depends on the p...

Page 10: ...10 ELECTRIC DIAGRAMS DEHUMIDIFIER ELECTRIC WIRING PUMP CONNECTION WIRING...

Page 11: ...articles The filter must be cleaned a minimum of every two weeks not doing so could invalidate the units warranty Please use the following steps Remove the filter Clean both sides of the filter with t...

Page 12: ...m 35 rh to 90 rh It is suitable for applications residential buildings offices museums archives garages and storage rooms Temperature Range 5 C 32 C Relative Humidity Range 35 90 rh Rated Voltage 230V...

Page 13: ...lly It is recommended to switch off the dehumidifier The ambient air humidity is lower than 35 rh Under this condition the dehumidifier becomes inefficient and little water will be collected The air f...

Page 14: ...Defective control assembly Please contact Meaco The unit does not defrost Defective bypass relay valve Please contact Meaco Defective control assembly Please contact Meaco Defective bypass relay valv...

Page 15: ...ge caused by actions that deviate from those as described in the user s manual or by neglect 6 The warranty does not cover faults caused by dirt or by third party products 7 The warranty does not cove...

Page 16: ...to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and...

Reviews: