SAFTEY INFORMATION 

----------------------------------------------------------------------------------------------------------------------------- ----------

 

 
This air circulator must not be used in rooms under the following conditions:  
- Potentially explosive atmosphere 
- Aggressive atmospheres 
- Featuring a high concentration of solvents  
- An extremely high ratio of dust

  

- Commercial environments 
 

 

Keep Children Away: 

Do not allow children to play with or around this unit, which could result in injury. 

Be sure the unit is inaccessible to children when not attended. This appliance is not intended for use 
by  person  (including  children)  with  reduced  physical,  sensory  or  mental  capabilities,  or  lack  of 
experience and knowledge, unless they have been given supervision or instruction concerning use of 
the appliance by a person responsible for their safety. 

 

Keep Unit Grounded:

 Always operate the unit with a grounding plug and a grounded electrical outlet. 

A grounding plug is an essential safety feature that helps reduce the risk of shock or fire.  

 

Protect Power Cord from Damage: 

Never operate a unit with a damaged power cord, as this may 

lead to electrical or fire hazards. If the power supply cord is damaged, it must be replaced by a cord of 
the same type and amperage rating.  

 

Extension Cords: 

Extension cords must be grounded and able to deliver the appropriate voltages to 

the unit.  

 

Handle with  Care

:  Do  not  drop,  throw  or  crash  the  air  circulator.  Rough  treatment  can  damage  the 

components or wiring and create a hazardous condition.  

 

Run on Stable Surface: 

Always operate the unit on a stable, level surface, for example the floor or a 

strong counter, so that the air circulator cannot fall and cause injury.  

 

Keep Out of Water: 

Never operate the unit in pooled or standing water, as this may create a risk of 

injury from electrical shock. Do not store or operate outdoors. If electrical wiring or components become 
wet, thoroughly dry them before using the unit. If in doubt do not use the air circulator and consult a 
qualified electrician or a Meaco approved engineer.  

 

Keep Air Intakes Clear: 

Do not clog or block the air intakes by placing the air circulator too close to 

curtains, walls or anything that will restrict the air inlet. This may cause the unit to overheat and result 
in a fire or electrical hazard.  

 

Keep Electrical Components Dry: 

Never allow water inside the air circulator’s electrical components. 

If  these  areas  become  wet  for  any  reason,  thoroughly  dry  them  before  using  the  air  circulator.  If  in 
doubt, do not use the air circulator and consult a qualified electrician or a Meaco approved engineer.  

 

The operator must make the operating instruction available for the user and make sure that the user 
does understand the manual.   
 

 
 
 
 
 

Summary of Contents for MeacoFan 360

Page 1: ...r Circulator Instruction Manual MeacoFan 360 Personal Air Circulator Please read this instruction manual before using the air circulator and keep safe for future reference Thank you for choosing Meaco...

Page 2: ...eliver the appropriate voltages to the unit Handle with Care Do not drop throw or crash the air circulator Rough treatment can damage the components or wiring and create a hazardous condition Run on S...

Page 3: ...ns potentially dangerous voltages internally and the cover should not be removed All service or maintenance work should be carried out by qualified personnel If you require assistance please contact M...

Page 4: ...of the fan In order to do this see the diagram below The cable can be inserted into the fan either way up Do not try and force the connection 1 Front guard 2 Front shell 3 Blade nut 4 Fan blades 5 Mo...

Page 5: ...to start and stop the sideways oscillation left and right Press the button once to turn the oscillation on and press the button again to stop the motion in doing so you can fix the direction of the fa...

Page 6: ...s 5 C 40 C Humidity operating range Non condensing Fan motor type DC Maximum air flow 360 cubic metres per hour Maximum air velocity c 4 8m sec Rated voltage and frequency 220 240V 50Hz Power consumpt...

Page 7: ...below 1 Using a screwdriver unscrew the small screw on the back of the fan on right hand side It is located towards the bottom of the fan 2 Squeeze four locks to pull away the front guard At the front...

Page 8: ...e fan from the mains for 40 minutes Increased noise level The fan blades are dirty Clean the fan blades see page 7 The fan blades or fan motor is loose Tighten the locking cap see page 7 There is a fa...

Page 9: ...neglect 6 The warranty does not cover faults caused by dirt or by third party products 7 The warranty does not cover accidental damage 8 All claims for compensation including consequential damage will...

Page 10: ...harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return...