background image

 

 

SAFTEY INFORMATION 

----------------------------------------------------------------------------------------------------------------------------- ----------

 

This dehumidifier must not be used in rooms under the following conditions:  
- Potentially explosive atmosphere 
- Aggressive atmospheres 
- Featuring a high concentration of solvents  
- An extremely high ratio of dust

 

 

 

Keep Children Away: 

Do not allow children to play with or around this unit, which could result in injury. 

Be sure the unit is inaccessible to children when not attended. This appliance is not intended for use by 
person (including children) with reduced physical, sensory or mental capabilities, or lack of experience 
and  knowledge,  unless  they  have  been  given  supervision  or  instruction  concerning  use  of  the 
appliances by a person responsible for their safety.

 

Keep Unit Grounded:

 Always operate the unit with a grounding plug and a grounded electrical outlet. 

A grounding plug is an essential safety feature that helps reduce the risk of shock or fire. 

 

Protect  Power Cord from Damage: 

Never operate  a unit with a  damaged power cord, as this may 

lead to electrical or fire hazards. If the power supply cord is damaged, it must be replaced by a cord of 
the same type and amperage rating. 

 

Extension Cords: 

Extension cords must be grounded and able to deliver the appropriate voltages to 

the unit. 

 

Handle with  Care

:  Do  not  drop,  throw  or  crash  the  dehumidifier.  Rough  treatment can  damage  the 

components or wiring and create a hazardous condition. 

 

Run on Stable Surface: 

Always operate the unit on a stable, level surface, for example the floor or a 

strong counter, so that the dehumidifier cannot fall and cause injury. 

 

Keep Out of Water: 

Never operate the unit in pooled or standing water, as this may create a risk of 

injury from electrical shock. Do not store or operate outdoors. If electrical wiring or components become 
wet, thoroughly dry them before using the unit. If in doubt do not use the dehumidifier and consult a 
qualified electrician or a Meaco approved engineer. 

 

Do Not Let Water Drip onto the Dehumidifier: 

Dry your bathroom by placing the dehumidifier outside 

of the room with the bathroom door open. Do not use your dehumidifier inside the bathroom. 

 

Keep Air Intakes Clear: 

Do not clog or block the air intakes by placing the dehumidifier too close to 

curtains, walls or anything that will restrict the air inlet. This may cause the unit to overheat and result 
in a fire or electrical hazard. 

 

Keep the Filter Clean: 

There is a filter on the air inlet to stop dust from getting inside the dehumidifier. 

If you allow the dust and dirt to build up on the filter, pressure on the fan motor will be increased and 
you will reduce the amount of water extracted from the air. Not cleaning the filter reduces the lifespan 
of the dehumidifier,  increases energy consumption  and decreases  water  extraction.  Please  examine 
and clean the filter every two weeks minimum.  

 

Keep Electrical Components Dry: 

Never allow water inside the dehumidifier’s electrical components. 

If  these  areas  become  wet  for  any  reason,  thoroughly  dry  them  before  using  the  dehumidifier.  If  in 
doubt, do not use the dehumidifier and consult a qualified electrician or a Meaco approved engineer. 

 

The operator must make the operating instruction available for the user and make sure that the user 
does understand the manual.   

 

 

Summary of Contents for MeacoWall 108B

Page 1: ...truction Manual MeacoWall 53B W MeacoWall 84B W and MeacoWall 108B W Dehumidifiers Please read this instruction manual before using the dehumidifier and keep safe for future reference Thank you for ch...

Page 2: ...r cannot fall and cause injury Keep Out of Water Never operate the unit in pooled or standing water as this may create a risk of injury from electrical shock Do not store or operate outdoors If electr...

Page 3: ...installed operated or stored in a non ventilated area then the room must be designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the re...

Page 4: ...ent local regulations non UK The unit is supplied without a plug and is expected to be connected to a fused spur by a qualified electrician following local regulations and laws Please refer to the uni...

Page 5: ...ehumidifier to dry a room and reach the desired relative humidity depends on the environmental conditions prevailing within the room For example the number of air changes with outside any sources of m...

Page 6: ...CATION Please keep the dehumidifier upright at all times prior to installation If the dehumidifier is inclined greater than 60 degrees then the dehumidifier should only be turned on 24 hours after it...

Page 7: ...Make sure the wall that the dehumidifier is being fixed to is strong enough to support its weight This dehumidifier must be used exclusively for drying the air If the dehumidifier has been in a horizo...

Page 8: ...s fitted ready to come out of the right of the dehumidifier as you look at it from behind If you wish to move the drain to the other side then you can do so by removing the side covers this should onl...

Page 9: ...he water is flowing downhill with no kinks or blockages You have the choice of fitting the drain on the right or left side The hose on the right is pre fitted if you wish to change to the left remove...

Page 10: ...The display will dim after 90 seconds of no keys being pressed ON OFF BUTTON Press the ON OFF button to turn the dehumidifier on or off CHILD LOCK Press the ON OFF button for five seconds to activate...

Page 11: ...d button quickly to choose between one of three different fan speeds low 1 medium 2 and high 3 The default setting for the fan speed is Fan Speed 1 Low FAN SPEED OPTIONS CONTINOUS Hold down the Fan Sp...

Page 12: ...l start to dehumidify again DEFROST MODE This dehumidifier is equipped with an automatic hot gas defrosting system When operating in low temperatures the surface of the evaporator will accumulate fros...

Page 13: ...ing the dehumidifier from the wall and without tilting the dehumidifier The image below only shows the dehumidifier on its side for clarity To remove the filter press the two single red buttons to the...

Page 14: ...n a wet area must comply with local laws We recommend electrical installation and servicing by a qualified electrician only OPERATING CONDITIONS This dehumidifier can be operated within an ambient tem...

Page 15: ...50Hz 220 240V 50Hz Air Flow m h 500 650 800 Noise Level dB A 44 44 46 Power Consumption kW 0 892 1 095 1 700 Running Current amps 4 1 5 1 7 9 Start up Current amps 21 25 39 Refrigerant R32 R32 R32 Dry...

Page 16: ...16 PERFORMANCE CURVES MEACOWALL 53B W DEHUMIDIFIER MEACOWALL 84B W DEHUMIDIFIER MEACOWALL 108B W DEHUMIDIFIER...

Page 17: ...s normal and is not a fault Compressor is not on The dehumidifier has just turned on Wait 3 minutes for the compressor to start up Unit is in defrost mode defrost symbol appears on the display This is...

Page 18: ...bnormal levels of chlorine would be anything above 2ppm and or a super chlorination above a maximum of 30ppm over a 24 hour period STORAGE If the machine will not be used for a long period of time tak...

Page 19: ...d in the user s manual or by neglect 6 The warranty does not cover faults caused by dirt or by third party products 7 The warranty does not cover accidental damage 8 All claims for compensation includ...

Page 20: ...m to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and...

Reviews: