SAFETY INFORMATION

ATTENTION

This dehumidifier must not be used in rooms under the following conditions:

Potentially explosive atmosphere

Aggressive atmospheres

Featuring a high concentration of solvents or chemicals

A high ratio of dust

Outside of the defined temperature ranges

Keep Children Away:

Do not allow children to play with or around this unit, which could result in injury. Be

sure the unit is inaccessible to children when not attended.

Keep the Unit Grounded

: The unit must be installed to a grounded supply in

ALL

applications by a qualified

electrician.

If the unit is to be installed in to a wet area (i.e. a swimming pool) please ensure that the mains connections meet
the criteria set out in section 602 of BS7671 other equivalent local regulation (non-UK)

Protect Power Cord from Damage:

Never operate a unit with a damaged power cord, as this may lead to

electrical or fire hazards. If the power supply cord is damaged, it must be replaced by a cord of the same
type and amperage rating.

Extension Cords:

This is not a suitable product to use with an extension lead, only use a fused spur.

Handle with Care:

Do not drop, throw or crash the dehumidifier. Rough treatment can damage the

components or wiring and create a hazardous condition.

Mount on Level Surface:

Ensure that the wall for mounting is level and true to avoid leakage and additional

vibration from the compressor.

Always secure the dehumidifier to a wall

.

Keep Out of Water:

Never operate the unit in pooled or standing water, as this may create a risk of injury

from electrical shock. Do not store or operate outdoors. If electrical wiring or components become wet,
thoroughly dry them before using the unit. If in doubt do not use the dehumidifier and consult a qualified
electrician or a Meaco approved engineer.

Keep Air Intakes Clear:

Do not clog or block the air intakes by placing the dehumidifier too close to anything

that will restrict the air inlet. This may cause the unit to overheat and result in a fire or electrical hazard.

Keep Filter Clean:

Always use a clean air filter. Do not allow any material to clog the filter, as this may

cause the dehumidifier to overheat. Never use without a filter. Always check, and if necessary, clean the
filter before switching the dehumidifier on. Do not allow oil, grease, or other contaminants to be drawn into
the dehumidifier. Do not clean the dehumidifier with organic solvents.

Keep Electrical Components Dry:

Never allow water inside the dehumidifier's electrical components. If

these areas become wet for any reason, thoroughly dry them before using the dehumidifier. If in doubt do
not use the dehumidifier and consult a qualified electrician or a Meaco approved engineer.

The operator must:

Make the operating instruction available for the user and make sure that the user does

understand the manual.

Summary of Contents for MeacoWall 53B

Page 1: ...Meaco Wall Mounted Dehumidifiers MeacoWall 53B W MeacoWall 72B W MeacoWall 103B W Please read the manual before installation INSTRUCTION MANUAL EN MeacoWall Series...

Page 2: ...is level and true to avoid leakage and additional vibration from the compressor Always secure the dehumidifier to a wall Keep Out of Water Never operate the unit in pooled or standing water as this m...

Page 3: ...uivalent local regulation non UK This unit is supplied without a plug and is expected to be connected to s fused spur by a qualified electrician following local regulations and laws Please make refere...

Page 4: ...e dehumidifier to dry a room and reach the desired relative humidity depends on the environmental conditions prevailing within the room For example the number of air changes with outside any sources o...

Page 5: ...e prevented from rolling around The dehumidifier must always be transported vertically The dehumidifier must always be secured to the wall Make sure that the wall that it is being fixed to is strong e...

Page 6: ...r water will leak from the dehumidifier 5 CONTINUOUS DRAINAGE This dehumidifier is designed to be connected to a permanent drain via a 16mm hose Make sure that the drain connection is running downhill...

Page 7: ...other side then you can do so by removing the side covers This should only be done by a qualified electrician and only when the unit s power supply has been turned off and isolated Remove the one scr...

Page 8: ...the water is flowing downhill with no kinks or blockages You have the choice of fitting the drain on the right or left side The hose on the right is pre fitted if you wish to change to left then remov...

Page 9: ...e keep the dehumidifier upright at all times prior to installation If the dehumidifier is inclined greater than 60 degrees then the dehumidifier should only be turned on 24 hours after it has been ins...

Page 10: ...how 88 and then the program version number for ten seconds This is to allow the relative humidity sensor to sample the air and to take a reading The display will dim after 90 seconds of no keys being...

Page 11: ...rol panel Repeat to deactivate Checking the relative humidity set point Press either the up or down arrow once to check what target relative humidity has been set to Setting the relative humidity set...

Page 12: ...N Off Timer When the unit is turned on use this button to determine when the dehumidifier will turn off On Timer When the unit is turned off use this button to determine when the dehumidifier will tur...

Page 13: ...put the code 66 Press the UP Button for 10s to enter the factory parameter setting Then please press the Up or Down Button to select the parameter 11 Press the Timer Button to confirm your setting Pre...

Page 14: ...ng when the dehumidifier reaches the target humidity Press the UP butt on to input the code 66 Press the UP button for 10s to enter the factory parameter setting Then please press the Up or Down Butto...

Page 15: ...umidifier is where the relative humidity measurements are made Keep this clear and clean at all times Defrosting In order to remove water from the air the temperature of the coils inside the dehumidif...

Page 16: ...or The filter can be removed without the need to remove the dehumidifier from the wall and without having to tilt the dehumidifier the image below only shows the dehumidifier on its side for clarity T...

Page 17: ...y It is not recommended to use the dehumidifier in temperatures below 10O C 9 ELECTRICAL CONNECTIONS This dehumidifier was designed to operate in a 230V 50Hz electrical installation Make sure that the...

Page 18: ...ise level at 1 metre dB A 44 46 48 Power Consumption kW 0 93 1 13 1 97 Running current amps 4 1 5 0 8 7 Start up current amps 4 3 5 85 10 Refrigerant R410a Drying Capacity in litres at 30 C 80 rh Per...

Page 19: ...19 EN Performance Curves...

Page 20: ...essor is not on The dehumidifier has just turned on Wait 3 minutes for the compressor to start up Unit is in defrost mode defrost symbol appears on the display This is normal and is not a fault The fa...

Page 21: ...ess levels will damage the dehumidifier and invalidate the warranty 2 Abnormal levels of chlorine would be anything above 2ppm and or a Superchlorination above a maximum of 30ppm over a 24 hour period...

Page 22: ...products The warranty does not cover accidental damage All claims for compensation including consequential damage will not be entertained To prevent unnecessary expenses we recommend that you always c...

Page 23: ...midifier If you do develop a fault within the first year then please do call us and if we cannot fix the problem over the phone we will be happy to collect the dehumidifier from you at our expense and...

Reviews: