background image

23 [EN]

Meaco are specialists in dehumidifiers and would welcome your comments and questions on this dehumidifier. If
you do develop a fault within the first year then please do call us and if we cannot fix the problem over the phone
we will be happy to collect the dehumidifier from you at our expense and repair or replace as appropriate.

Please save the box just in case this happens.

Meaco 08/16 – version 1.0

Summary of Contents for MeacoWall 53B

Page 1: ...Meaco Wall Mounted Dehumidifiers MeacoWall 53B W MeacoWall 72B W MeacoWall 103B W Please read the manual before installation INSTRUCTION MANUAL EN MeacoWall Series...

Page 2: ...is level and true to avoid leakage and additional vibration from the compressor Always secure the dehumidifier to a wall Keep Out of Water Never operate the unit in pooled or standing water as this m...

Page 3: ...uivalent local regulation non UK This unit is supplied without a plug and is expected to be connected to s fused spur by a qualified electrician following local regulations and laws Please make refere...

Page 4: ...e dehumidifier to dry a room and reach the desired relative humidity depends on the environmental conditions prevailing within the room For example the number of air changes with outside any sources o...

Page 5: ...e prevented from rolling around The dehumidifier must always be transported vertically The dehumidifier must always be secured to the wall Make sure that the wall that it is being fixed to is strong e...

Page 6: ...r water will leak from the dehumidifier 5 CONTINUOUS DRAINAGE This dehumidifier is designed to be connected to a permanent drain via a 16mm hose Make sure that the drain connection is running downhill...

Page 7: ...other side then you can do so by removing the side covers This should only be done by a qualified electrician and only when the unit s power supply has been turned off and isolated Remove the one scr...

Page 8: ...the water is flowing downhill with no kinks or blockages You have the choice of fitting the drain on the right or left side The hose on the right is pre fitted if you wish to change to left then remov...

Page 9: ...e keep the dehumidifier upright at all times prior to installation If the dehumidifier is inclined greater than 60 degrees then the dehumidifier should only be turned on 24 hours after it has been ins...

Page 10: ...how 88 and then the program version number for ten seconds This is to allow the relative humidity sensor to sample the air and to take a reading The display will dim after 90 seconds of no keys being...

Page 11: ...rol panel Repeat to deactivate Checking the relative humidity set point Press either the up or down arrow once to check what target relative humidity has been set to Setting the relative humidity set...

Page 12: ...N Off Timer When the unit is turned on use this button to determine when the dehumidifier will turn off On Timer When the unit is turned off use this button to determine when the dehumidifier will tur...

Page 13: ...put the code 66 Press the UP Button for 10s to enter the factory parameter setting Then please press the Up or Down Button to select the parameter 11 Press the Timer Button to confirm your setting Pre...

Page 14: ...ng when the dehumidifier reaches the target humidity Press the UP butt on to input the code 66 Press the UP button for 10s to enter the factory parameter setting Then please press the Up or Down Butto...

Page 15: ...umidifier is where the relative humidity measurements are made Keep this clear and clean at all times Defrosting In order to remove water from the air the temperature of the coils inside the dehumidif...

Page 16: ...or The filter can be removed without the need to remove the dehumidifier from the wall and without having to tilt the dehumidifier the image below only shows the dehumidifier on its side for clarity T...

Page 17: ...y It is not recommended to use the dehumidifier in temperatures below 10O C 9 ELECTRICAL CONNECTIONS This dehumidifier was designed to operate in a 230V 50Hz electrical installation Make sure that the...

Page 18: ...ise level at 1 metre dB A 44 46 48 Power Consumption kW 0 93 1 13 1 97 Running current amps 4 1 5 0 8 7 Start up current amps 4 3 5 85 10 Refrigerant R410a Drying Capacity in litres at 30 C 80 rh Per...

Page 19: ...19 EN Performance Curves...

Page 20: ...essor is not on The dehumidifier has just turned on Wait 3 minutes for the compressor to start up Unit is in defrost mode defrost symbol appears on the display This is normal and is not a fault The fa...

Page 21: ...ess levels will damage the dehumidifier and invalidate the warranty 2 Abnormal levels of chlorine would be anything above 2ppm and or a Superchlorination above a maximum of 30ppm over a 24 hour period...

Page 22: ...products The warranty does not cover accidental damage All claims for compensation including consequential damage will not be entertained To prevent unnecessary expenses we recommend that you always c...

Page 23: ...midifier If you do develop a fault within the first year then please do call us and if we cannot fix the problem over the phone we will be happy to collect the dehumidifier from you at our expense and...

Reviews: