3 [EN]
Electrical Installation
The unit must be installed to a grounded supply in
ALL
applications
If the unit is to be installed in to a wet area (i.e. a swimming pool) please ensure that the mains connections
meet the criteria set out in section 602 of BS7671 other equivalent local regulation (non-UK)
This unit is supplied without a plug and is expected to be connected to s fused spur
by a qualified electrician following local regulations and laws. Please make
reference to the unit’s start-up voltage before connecting to a power supply.
All units are supplied with a 3 metre 16 amp cable.
53L
72L
103L
Rated Voltage
220 - 240V / 50Hz
Power Consumption (kW)
0.93
1.13
1.97
Running current (amps)
4.1
5.0
8.7
Start-up current (amps)
4.3
5.85
10