background image

SAFETY WARNING &

OPERATING PRECAUTIONS

the protection circuit activates, immediately discon-
nect the unit from the power source and allow it to
cool.

The compressor should take approximately 15 min-
utes to cool depending on ambient conditions. The
compressor  protection  circuit  will  automatically
reset when the temperature returns to a safe opera-
ting level.

NOTE:  The  thermal  cut  out  will  operate  when
the motor reaches 105°C. The cylinder head will
operate at a higher temperature.

POWER CONNECTION:

SAFE HANDLING:

INFLATION:

STOPPING AND RESTARTING:

Use  caution  when  connecting  the  unit  to  a  power
source, as batteries can vent explosive gasses. Avoid
connections  that  could  produce  a  spark.  Consult
your  vehicle’s  manual  or  a  qualified  mechanic  for
proper connection procedures.

Only  move  and  hold  the  unit  by  the  carry  handle.
NEVER  carry  the  air  compressor  by  the  hose  or
power cords.

Only  inflate  the  tyres  to  the  manufacturer’s  recom-
mended  pressure  (consult  your  vehicle’s  manual  or
check for a sticker inside the driver’s door frame or
glove  box  for  vehicle  manufacturer  specifications).
DO NOT over inflate, as tyre failure or serious injury
could occur.

Turning the air compressor “ON” at high pressure can
overload  the  unit  and  result  in  blowing  the  fuse  or
tripping  the  circuit  breaker.  If  starting  at  a  higher
inflation pressure, it is a good idea to turn the com-
pressor “ON”  first  before  attaching  the  hose  to  the

NOTE:  This  air  compressor  is  not  fitted  with  a
pressure relief valve.

IMPORTANT:  Please  refer  to  the  front  of  this
manual  for  full  details  on  the  maximum  duty
cycle  of  the  air  compressor.  Always  allow  your
compressor to cool before reuse.

WARNING

Mean Mother Air Compressors generate a

lot of heat so wear appropriate gloves to

protect your hands. DO NOT touch the unit

with bare hands after operation, use the

carry handle. Always allow the compressor

to cool completely before storage.

When using this air compressor, safety precautions should always be followed to reduce the risk of

personal injury and damage to the air compressor.

WORKING AREA CONDITIONS:

KEEP CHILDREN AWAY:

USE LEATHER GLOVES:

USE SAFETY GLASSES:

CORRECT USE OF COMPRESSED AIR:

Keep the working area well lit. DO NOT use this air
compressor  in  the  presence  of  flammable  gases  or
liquids.  Use  the  air  compressor  in  dry  conditions
only to avoid potential risk of electrical shock.

Keep  children  away  from  working  area.  NEVER  let
children operate the air compressor.

When handling the air compressor, always use hand
protection to eliminate the possibility of burns.

Always wear approved safety glasses when working
with  compressed  air  from  your  air  compressor.
NEVER aim the air stream at anyone’s eyes or skin.

DO NOT use the air compressor for pumping, comp-
ressing  or  transferring  any  gas  or  liquid  other  than

tyre valve. If you are stopping the air compressor and
restarting  during  an  inflation  operation,  then  you
should  remove  the  hose  from  the  valve  once  you
have turned the air compressor “OFF”, then turn the
air compressor “ON” and reconnect to the tyre valve.

Page 05

Copyright © 2020 Haigh Australia Pty Ltd 

Summary of Contents for ADVENTURER IV

Page 1: ...cuit Protection 45mm 1 8 Diameter Cylinder Built in Air Filter 0 65HP 0 48kW Permanent Magnet Motor 5m 16 5 Rubber Air Hose with Quick Connectors Dual Control Wireless via Remote and Manual Powerful 1...

Page 2: ...not cause harmful interference and 2 this device must accept any interference received including interference that may caused undesired operation Due to continuing improvements actual product may diff...

Page 3: ...On Fitting 1 x Thumb Lock Quick Connector 0 150 PSI 0 10 BAR 0 1 034 kPa 27cm x 14 5cm x 19cm 10 6 x 5 7 x 7 5 5 6kg 12 3lb Metal Sand Tray with Rubber Feet Can be Permanently Mounted to a Vehicle Ca...

Page 4: ...e at 105 C 220 F Cooling Fins 2 4m 7 8 with Durable Battery Clamps ON OFF Toggle Switch Premium Wireless Remote System 2 4GHz 5 5dBm 3 6mW Powered by 1 x 12V 23A L1028 Alkaline Battery Circuit Breaker...

Page 5: ...POWER CONSUMPTION OVERHEATING PROTECTION F A D Free Air Delivery rating is the actual quantity in Litres per Minute Gallons Per Minute and Cubic Inches Per Minute of compressed air that is discharged...

Page 6: ...not fitted with a pressure relief valve IMPORTANT Please refer to the front of this manual for full details on the maximum duty cycle of the air compressor Always allow your compressor to cool before...

Page 7: ...this air compressor in any way This will void the manufacturer s warranty Extra caution should be taken when inflating small objects such as small tyres bicycle tyres and sporting balls as rapid infla...

Page 8: ...first before attaching the hose to the tyre valve If you are stopping the air compressor and restarting during an inflation operation then you should remove the hose from the valve once you have turn...

Page 9: ...he hose from the valve once you have turned the air compressor OFF then turn the air compressor ON and reconnect to the tyre valve This reduces the unnecessary strain applied to the compressor maximis...

Page 10: ...rew type fitting is threaded onto the valve correctly and has a good seal TROUBLESHOOTING Vehicle battery or power source should be in good working order and fully charged This should be used as a gui...

Page 11: ...f purchase b full details of the alleged defect The customer must make the Product available to Haigh Australia or its authorised repair agent for inspection and testing If such inspection and testing...

Page 12: ...ion between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician...