5
15
21
22
23
19
18
16
20
17
Device
temperature
measured
The number
of overload
times
Overload
duration
The number
of short
circuits times
Busload
measured
Maximum
device
temperature
during tracking
period
Device
temperature
alarm
Busload alarm
Maximum
output current
during tracking
period
2bytes
2bytes
4bytes
2bytes
1byte
2bytes
1bit
1bit
2bytes
4bytes
2bytes
,°C
temperature
(DPT=9.001)
Pulses
(DPT = 7.001)
Pulses
(DPT = 7.001)
Pulses
(DPT = 7.001)
percentage,
0~255%
( DPT=5.004)
,°C
temperature
(DPT=9.001)
alarm
(DTP = 1.005)
alarm
(DTP = 1.005)
current,mA
(DPT=9.021)
electric current,A
(DPT=14.019)
current,mA
(DPT=7.012)
Measurement
Analysis
Analysis
Analysis
Measurement
Measurement
Alarm
Alarm
Measurement
The device sends the measured device temperature
value in
at regular intervals.
°C
The device sends the number counted value of
overload at regular intervals.
The device sends the total duration time in
overload in second
The device sends the number counted value of
short circuit at regular intervals.
The device sends the measured Bus load
value in % at regular intervals [0-255%]
The device sends the measured device
temperature value in
at the end of each period.
°C
When the measured value is above the threshold a
telegram with value 0 or 1 is sent. When the
measurement values return to the normal range
(less than the hysteresis) a telegram with value 0
or 1 is sent.
When the measured value is above the threshold
a telegram with value 0 or 1 is sent. When the
measurement values return to the normal range
(less than the hysteresis) a telegram with value 0
or 1 is sent.
The device sends the measured output current
value in A or mA at the end of each period.
CRT
CRT
CRT
CRT
CRT
CRT
CRT
CRT
C
RT
24
26
27
28
31
34
Time load
detached
Count 1
Duration 1
Alarm 2
-----
-----
-----
Alarm 3
Alarm 4
4bytes
2bytes
4bytes
time lag(s)
( DPT=13.100)
Pulses
(DPT = 7.001)
time lag(s)
( DPT=13.100)
Analysis
Group Alarm
Group Alarm
On activation the device sends the time counter
value of load detachments
The device sends the number counted value of
threshold events for output current, output voltage
or device temperature.
The device sends the total duration time
(in second) for output current, output voltage or
device temperature.
CRT
CRT
CRT
25
Alarm 1
1bit
Alarm
(DTP = 1.005)
Group Alarm
When the measured value is above/below the
threshold a telegram with value 0 or 1 is sent. When
the measurement values return to the normal range
(less/higher than the hysteresis) a telegram with
value 0 or 1 is sent.
CRT