EHC-PF
.
12
.
SCALE
--------------------------CABLE(9 pins)---------------------------
HOST
DB9(Female)
--------------DB9(Male)------------DB9(Female) ---------------
DB9(Male)
PIN2 TXD
------------------2--------------------------2-----------------------
PIN2 RXD
PIN3 RXD
------------------3--------------------------3-----------------------
PIN3 TXD
PIN5 GND
------------------5--------------------------5-----------------------
PIN5 GND
PIN4 DSR
------------------4--------------------------4-----------------------
PIN4 DTR
PIN6 DTR
------------------6--------------------------6-----------------------
PIN6 DSR
PIN7 CTS
------------------7--------------------------7-----------------------
PIN7 RTS
PIN8 RTS
------------------8--------------------------8-----------------------
PIN8 CTS
PIN1 NC
------------------1--------------------------1-----------------------
PIN1 NC
PIN9 NC
------------------9--------------------------9-----------------------
PIN9 NC
NOTE: PIN4 and PIN6, PIN7 and PIN8 are shor ted in the scale!
5.4.12
RS-232 cable connects between scale and OS-203/213:
5.5
Date and time setting
5.5.1
Under the normal working mode, press and hold ON/OFF and 5 key for more than 3s to enter into this mode. In
this mode, you can set the system date and time.
NOTE: the date and time in scale will be lost after the scale power off if no RTC backup battery is installed.
5.5.2
After entering into this mode, the weight window will display “
Setup
”, the unit price window will display
“
dAtE
”(date, prompt to input date) and the total unit price will display the current date xx.xx.xx. Use the numerical
keys to input the date (format: YY.MM.DD), use ENTER key to confirm and go to the time setting mode.
5.5.3
When the WEIGHT window displays “
Setup
”
,
the UNIT PRICE displays “
time
” (time, prompt to input time) and the
TOTAL PRICE window displays the current time xx.xx.xx, Use the numerical keys to input the time (Format
:
hh.mm.ss)
,
press ENTER to confirm the input and exit this mode.
5.6
Group Code Setting
5.6.1
Under the normal working mode, press and hold ON/OFF and 6 key for more than three seconds to enter this
mode. In this mode, you can set group code.
5.6.2
The WEIGHT window displays “
Setup
”, the UNIT PRICE window displays “
GROUP.C
” and the TOTAL PRICE window
displays group code xx (the default Id code is
00
). Its range is 00 to 99.
5.6.3
Use the numerical keys to input group code, then press ENTER key to confirm the input and exit this mode.