Operation
Place the scale on a level and steady surface, press this key, the scale will show
"O" after self-examination, indicating the scale is ready for weighing.
Place a container on the platter, press this key. When the container is removed,
the scale will display the negative reading equal to the weight of the container. To
re-set to zero, press the key again.
When the scale is ON, press the key to turn off. The scale will automatically turn
off if the "AUTO OFF" function is activated.
Press the button to change measuring unit between kg, g, lb:oz and oz
Calibration
1.
When the scale is off, keep pressing MODE key first, then press ON/TARE key to power on the scale,
the scale will display "8888"m then display the inner code (0-15000). Now release MODE key.
2.
Press MODE key again, the scale displays "CAL", then display "2000". Now put the 2KG weights on
the platter, and then the scale will display "PASS" after a few seconds and back to normal weighing
mode.
Auto-off Time Setup
Press MODE key until the scale displays "OFF-x" (x-0, 1, 3, 5, 10, 30). Press MODE key again to choose
the time, pre ON/TARE key to confirm.
Note: Default setting: OFF-3