Troubleshooting
9.1 Troubleshooting
SYMPTOM
PROBABLE CAUSE
REMEDY
Will not power on
Power cord not plugged in or properly
connected. Power outlet not supplying electricity.
Battery discharged. Other failure.
Check power cord connections. Make sure
power cord is plugged into the power outlet.
Check power source. Replace batteries. Or
service required.
Unable to zero the
display or will not
zero when turned on
Load on scale exceeds allowable limits.
Load on scale is not stable.
Load cell damage.
Remove load on scale.
Wait for load to become stable.
Service required.
Lo.bAt is shown
Battery is discharged
Charge battery
9.2 Battery and Charging
Power is supplied by an internal rechargeable 6V lead-acid battery (4Ah). When “Lo.bAt” is displayed, the battery must
be recharged. Plug in the AC power adapter to recharge the battery. The scale may continue to be used on AC power
during charging. Full charging time is approximately 10-12 hours.
Battery life and recharge time will vary with use. Over time, the operating time per each full charge will degrade. If the
operating time is no longer acceptable, the battery must be replaced. When storing the scale for extended periods, the
battery must be charged every 90 days to avoid premature performance degradation.