Page 31
1330SE - Servce & Parts Manual
November 2021
Secton 11 - Control System
80
Over 80% Load Warning
All Models
Platform capacity close to limit of weight (consider
not adding more load).
81
Right Drive Motor Short
1930SE/Micro19®
Check right drive motor and wiring, check motor
controller and wiring.
82
Right Brake Coil
Brakes Should Be 46
Ohms On Micro19
And 26 Ohms For All
Others
•
All Models
Check battery voltage, check right brake terminals,
check brake module and wiring, check contactor,
check option code, check fuse near motor
controller, replace ECU.
83
Left Brake Coil
All Models
Check battery voltage, check left brake terminals,
check brake module wiring, check contactor.
1930SE/Micro19®
Check drive motor terminals, check fuse connected
to motor controller, replace motor controller.
85
Brake Release Switch
Closed
1930SE/Micro19®
ONLY
Turn brake release switch off.
86
Raised Brake Release Fault
1930SE ONLY
Brake release switch engaged when elevated.
87
Brake Release Switch Fault
1930SE ONLY
Brake release switch is open.
89
Drive Motor Field Open Fault
All Models
Check wiring on motors, check wiring to motor
controller.
90
Over 90% Load Warning
All Models
Platform getting close to weight capacity.
91
Left Drive Motor Short
All Models
Check wiring to motor, check wiring to motor
controller.
92
Right Drive Motor Short
All Models
Check wiring to motor, check wiring to motor
controller.
99
Over 99% Load Warning
All Models
Platform has reached load capacity.
OL
Platform Overloaded
All Models
Remove excess load.
LL
Tilted
All Models
Check wiring to tilt sensor, recalibrate tilt.
H9
Height Not Calibrated
All Models
Calibrate height.
CH
Not A Fault Code
All Models
Machine is in chassis controls.
Option Code For Machines
Model
Older
With Overload (Yellow Gate)
MICRO19®
To Serial #16900460 58
E2
From Serial #16900461 62
MICRO19XD®
N/A
E3
MICRO26®
N/A
27
1930SE
58
--
2632SE, 3346SE, 4046SE, 4555SE
30, 26
A7
MME20, MME25
N/A
A7