March 2008
"2047ES / 2647ES / 3247ES" Service & Parts Manual - CE Specifications
Page 3-6
GP102 - EZcal Help Messages (continued)
TOO HIGH - DRIVE PREVENTED
A drive function has been selected but the platform is raised above the “MAX DRIVE” setting (if
enabled). The drive function will be prevented until the platform is lowered. LED flash code 8.
TOO HIGH - LIFT UP PREVENTED
The lift/up function has been selected but the platform is raised above the “MAX LIFT” setting (if
enabled). The lift/up function will be prevented until the platform is lowered. LED flash code 8.
UP/DOWN SELECT INPUTS ACTIVE TOGETHER!
The up select (P2-3 and/or P2-5) and the down select (P2-4 and/or P2-6) are active together - the
GP102
cannot determine the vehicle use. All vehicle operation will be prevented until the problem is
corrected. LED flash code 2.
VEHICLE OVERLOADED
The estimated load in the platform exceeds the “OVERLOAD AT” setting in the “ADJUSTMENTS”
“LOAD” menu. The
GP102
will activate the cutout to prevent vehicle operation until the platform load is
reduced. LED flash code 8.
VEHICLE TILTED
Either the “X” or “Y” tilt (measured by the
GP102
integral tilt sensor) exceeds the “X TRIP” or “Y TRIP”
setting in the “ADJUSTMENTS” “TILT” menu. LED flash code 8.
WAITING FOR B+ ON P2-12
The supply on P2-12 provides power for the outputs P3-1/2/3/4. The
GP102
cannot function if the supply
is not present. Since the supply on P2-12 is switched to P3-4, vehicle operation will be prevented. LED
flash code 7.
WAITING FOR NEUTRAL
When the
GP102
is powered up, all controls must be in neutral to allow safe testing of the fail-safe
output; no functions are allowed until testing is complete. LED flash code 2.