"2047ES / 2647ES /3247ES" Service & Parts Manual - CE Specifications
March 2008
Page 6-9
ELECTRIC SCHEMATICS
NOTES:
(Unless otherwise specified)
1. Switch
S1
BASE/PLATFORM
makes contact from the CENTER to the LEFT position
when placed in
BASE
.
2. Switch
S2
UP/DOWN
makes contact from the CENTER to the LEFT position when the
switch is held in the CONTACT position and automatically returns to the CENTER position
when released.
3. Switch
LS1
breaks the N/C set of contacts and makes the N/O set of contacts when the
platform reaches approximately 7 feet.
4. Switch
LS2 and LS3
makes the N/C set of contacts when the Pothole Bars are down and
locked in place.
S1
S2
ART_2236
ART_2470
LS1
A12
LS2 & LS3