Page 102
Speed Level Seres - Servce & Parts Manual
January 2019
Secton 8 - Troubleshootng - 3084RT Models
Selection
ID
EZ-Cal Readout
Explanation
2F
OUTPUTS
2F-1
P4-1
Choke (gas engine) or pre-heat (diesel). ON= Choke or Pre-heat
activated
2F-2
P4-2
Engine Start. ON= Starter activated
2F-3
P4-4
Throttle Solenoid. ON= Throttle solenoid pulled in
2F-4
P4-5
Fuel to fuel select switch. ON= fuel system activated
2F-5
P4-6
Fuel to fuel select switch. ON= fuel system activated
2F-6
P4-7
Alternator Excite. ON= power to activate alternator charge
2F-7
P4-8
Ignition. ON= power to ignition coil (gas) or fuel hold solenoid (diesel)
2F-8
P4-10
Rear Wheel Bi-pass Valves. ON= Valves powered, rear wheels in
bi-pass
2F-9
P4-12
Proportional Valve. ON= Proportional valve activated for lift and drive
operation
2F-10
P4-14
Down Valves. ON= Down valves activated for platform lower
operation
2F-11
P5-1
Lift Valve. ON= Lift valve activated for platform Lift
2F-12
P5-2
Steer Right. ON= steer right valve activated
2F-13
P5-3
Steer Left. ON= steer left valve activated
2F-14
P5-4
Drive Forward. ON= drive forward valve activated
2F-15
P5-5
Drive Reversed. ON= drive reverse valve activated
2F-16
P5-6
Alarm. ON= alarm activated (default alarm in Down, may be selected
for other modes)
2F-17
P5-7
High Torque. ON= high torque valve activated (drive range toggle in
down position)
2F-18
P5-8
High Speed. ON= high speed valve activated (drive range toggle in
up position)
2F-19
P5-9
Hour Meter. ON= Meter powered up
2F-20
P5-12
Power Supply to limit switch and TBM module - should be ON when
system powered
2F-21
P6-1
Rear Pitching Valve. ON= rear pitching valve activated for Platform
Rear Leveling
2F-22
P6-2
Front Pitching Valve. ON= Front Pitching valve activated for Platform
forward Level
2F-23
P6-3
Outrigger – Not used
2F-24
P6-4
Left Rolling Valve. ON= Left valve activated for platform Level Left
2F-25
P6-11
Axle Lock Valves. ON= Axle valves powered, front axle will oscillate
2G
LOG
2G-1
Cal Date
Date of Load Sense calibration (CE option only)
2G-2
Software
MEC specific software version
2G-3
Powered
Accumulated time GP400 powered up (red LED on)