Page 129
Speed Level Seres - Servce & Parts Manual
January 2019
Secton 9 - Troubleshootng - 3084ES Models
Adjustments & Setups
2684ERT, 3084ERT (SPEED LEVEL)
EZ-CAL MENU
SYMBOL
KEY FUNCTIONS
EZ-Cal Flow Chart
Chart 1 of 2
ESC/ENTER BUTTONS
To move back and forth between
Menu and sub-menu
LEFT/RIGHT BUTTONS
Select menus and setting to be adjusted
UP/DOWN BUTTONS
Adjust setting values
HELP
PRESS ENTER
1
DIAGNOSTICS
2
ACCESS LEVEL
3
ADJUSTMENTS
4
SETUPS
5
ENTER
ERROR
MESSAGE
ENTER
LOGGED
MESSAGES
PRESS RT & LT
ARROWS TO VIEW
PREVIOUS
ERRORS &
MESSAGES
ENTER
SYSTEM
2A
PLATFORM
2B
GROUND
2C
INPUTS
2D
ANALOGS
2E
SEE
CHART
# 2
ACCESS LEVEL
2
FOR
CALIBRATIONS
ACCESS LEVEL
1
FOR
ADJUSTMENTS
ENTER
ENTER
OUTPUTS
2F
ENTER
CHANGE
DEFAULTS
5A
5A-1
5A-2
CUSTOMER
21=XX84ERT
mark2
ENTER
= DO NOT CHANGE
= DO NOT CHANGE
RUN SYSTEM
TESTS
SELF-TEST
MODE
LOG
2G
MODEL
2?=XX84ERT
mark2 ANSI
OR
4=XX84RT
mark2 CE
SPEED
30%
4D-1
4D-2
4D-3
ELEV DRIVE
COMP
30%
4D-4
EXCEL
0.7 SEC
4D-5
DRIVE
4A
4B
4C
STEER
4D
4E
OUTRIGGERS
OPTIONAL
4F
TILT
4J
ALARMS
4M
UP MIN
5%
4C-1
UP MAX
54%
4C-2
DOWN MIN
0%
4C-3
DOWN MAX
0%
4C-4
ACCEL
1.2 SEC
4C-5
DECEL
0.5
4C-6
FWD MIN
5%
4A-1
FWD MAX
60%
4A-2
REV MIN
5%
4A-3
REV MAX
60%
4A-4
ACCEL
1.5 SEC
4A-5
DECEL
1.2 SEC
4A-6
STOP DECEL
1.0 SEC
4A-8
FWD MIN
5%
4B-1
FWD MID
0%
4B-2
FWD MAX
30%
4B-3
REV MIN
5%
4B-4
REV MID
0%
4B-5
REV MAX
30%
4B-6
OUT MIN
20%
4E-1
OUT MAX
100%
4E-2
IN MIN
20%
4E-3
IN MAX
100%
4E-4
ACCEL
3.0 SEC
4E-5
DECEL
3.0 SEC
4E-6
OUTRIGGERS
2= DRI
4F-1
EXTEND
50%
4F-2
LEVEL
35%
4F-3
RETRACT
0%
4F-4
DEBOUNCE
0.35 SEC
4F-5
INITIAL
0.5 SEC
4F-6
X TRIP
2.0°
4J-1
Y TRIP
2.0°
4J-2
DELAY TRIP
1.0 SEC
4J-3
DELAY CLEAR
0.5 SEC
4J-4
DRIVE
SELECT AS
NEEDED
4M-1
LIFT
2= DOWN +
SELECT AS
NEEDED
4M-2
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
PRE- LEVEL
0.0 SEC
4F-7
4F-9
OVERLOAD
4K
TRIP @
0% ANSI
110% CE
4K-1
LAMP @
0%
4K-2
ALARM @
0%
4K-3
@ HEIGHT
0%
4K-4
SAFE DOWN
18%
4K-5
DELAY TRIP
1.5 SEC
4K-6
DELAY CLEAR
1.5 SEC
4K-7
ENTER
DRIVE
ELEVATED
LIFT
SC +
40%
SC X
0%
DECK
4F-10
4F-11
X TILT TARGET
0.2 DEG
Y TILT TARGET
0.2 DEG
TILT SLACK
0.3 DEG
4G
ENTER
4G-1
4G-2
4G-3
4G-4
4G-5
4G-6
UP
53%
DOWN
0%
OUT
0%
IN
0%
ACCEL
1.0 SEC
DECEL
1.0 SEC
GROUND
MODE
4H
AIRTRAX
(NOT USED)
4H-1
4H-2
4H-3
4H-4
4H-5
4H-6
4H-7
4H-8
HI MIN
HI BREAK
HIGH MAX
HI BREAK @
LO MIN
LO BREAK
LO MAX
LO BREAK @
ENTER
ENTER
TILT #2
4J-5
@ HEIGHT
101%
4J-5a
X TRIP 2
1.5 DEG
4J-5b
Y TRIP 2
1.5 DEG
4J-5c
HEIGHTS
4N
ELEVATION@
15%
4N-1
TILT
1= WHEN
ELEVATED
4M-3
4N-2
4N-3
4N-4
4N-5
4N-6
4N-7
4N-8
MAX DRIVE
101%
ARMGUARD
101% ANSI
9% CE
MAX LIFT
98%
OVERLOAD
0% ANSI
0% CE
SAFE-DOWN
18%
OVERLOAD 2
101%
TILT 2
101%
MAX HEIGHT
98%
4C-7
ARM GUARD
4C-8
DELAY
BELOW ELEV
0.0 ANSI
2.0 SEC -CE
4C-9
TIME
0.0 ANSI
2.0 CE
4C-8a
@ HEIGHT
101% ANSI
9% CE
4C-8b
ENTER
ENTER
OVERLOAD 2
4K-8
@ HEIGHT
101%
4K-8a
SCALE
100%
4K-8b
POTHOLE
101%
4N-9
MAX HEIGHT
101%
4A-9
ACCEL
1.5 SEC
4B-7
DECEL
1.2 SEC
4B-8
DECEL
0.2 SEC
4D-6
TILT FILTER
6
4F-8
TILT
SETUPS
5B
HEIGHT
SETUPS
5C
LOAD
SETUPS
5D
INTERLOCKS
5E
5B-1
5B-2
ELEVATED
TILT
SHUTDOWN
5B-3
5C-1
ELEVATION @
15%
5C-2
CALIBRATE
HEIGHT
SEE
INSTRUCTIONS
5C-5
TILT
CORRECTION
1= Y+
5C-4
SAMPLES@
0.30 SEC
5C-6
SLOW DOWN
10%
5E-1
TRIGGER ONLY
10.0 SEC
5E-6
STARTER DELAY
10.0 SEC
5E-2
5E-3
5D-1
CALIBRATE
LOAD
SEE INST
5D-2
FAULTY LOAD
-100%
5D-3
DYNAMIC
SCALE
.95
ENTER
ENTER
ENTER
ENTER
5C-3
MIN LIFT
1.0 SEC
5D-4
DELAY UP
0.0 SEC
5D-5
DELAY DOWN
0.0 SEC
5E-4
TRIGGER WAIT
1.0 SEC
FUNCTION HOLD
0.2 SEC
THROTTLE DELAY
0.00 SEC
5E-7
AUTOglow
0.0 SEC
MAXpositrack
30%
4A-2a
MAXhighspeed
95%
4A-2b
MAXpositrack
30%
4A-4a
MAXhighspeed
95%
4A-4b
ENTER
ENTER
AXLE TILT#2
0.0 DEG
4J-5d
AXLE TILT
3.0 DEG
5B-4
5E-5
THROTTLE HOLD
5.0 SEC
5E-9
JOY FILTER
5
5E-8
BRAKE DELAY
0.0 SEC
ENTER
ENTER
DECELhs
2.0 SEC
4A-7
5A-3
JOYSTICK
SWITCHED
OR
HALL-EFFECT3
CALIBRATE
LEVEL
SEE INST
TILT
SHUTDOWN
0= NEVER
1= LIFT & DRIVE
5F-1
GEN LOW
48 VOLTS
5F-6
BATTERY 100%
0.0V
5F-2
GEN HIGH
59.5 VOLTS
5F-3
5F-4
5K GEN
NO
5F-5
BATTERY 0%
0.0V
GENERATOR
5F
GEN RMS
0.0A
5G-1
FAN ON
2.5V
5G-2
FAN OFF
2.5V
FAN
5G
ENTER
ENTER
ENTER