Page 5
3084ES Speed Level
TM
- Operator’s Manual
August 2020
Electrocution Hazard
ELECTROCUTION HAZARD!!! THIS MACHINE IS NOT INSULATED!
DEATH OR SERIOUS INJURY will result from contact with or inadequate
clearance from any electrically charged conductor�����
You must maintain a CLEARANCE OF AT LEAST 10 FEET (3�����05 m)
between any part of the machine, or its load, and any electrical line or
apparatus carrying over 300 Volts up to 50,000 Volts����� One foot (30�����5 cm)
additional clearance is required for every additional 30,000 Volts�����
Observe Minimum Safe Approach Distance�����
DO NOT work in close proximity to, or in contact with, energized power lines and electrical
equipment. This machine is not insulated and WILL NOT protect the operator from injury or the
machine from damage.
Refer to Table and all applicable governmental regulations for the minimum safe distances from
energized power lines and electrical equipment.
ART_3060
ART_3070
Mnmum Save Approach Dstance
Voltage
Minimum Safe Approach Distance
Phase to Phase
Feet
Meters
0 to 300 Volts
Avoid Contact
Over 300V to 50kv
10
3.05
Over 50KV to 200KV
15
4.60
Over 200KV to 350KV
20
6.10
Over 350KV to 500KV
25
7.62
Over 500KV to 750KV
35
10.67
Over 750KV to 1000KV
45
13.72
DO NOT touch the machine if it contacts energized power lines�����
Personnel in the platform:
Move away from the platform rails,
DO NOT attempt to operate the machine, and
DO NOT touch any part of the machine until energized power lines are shut off.
Personnel on the ground:
DO NOT approach the machine and
DO NOT touch or attempt to operate the machine until energized power lines are turned off.
Do not operate the machine during electrical storms or lightning.
DO NOT use the machine as a ground for welding unless properly equipped with a weld line to
platform option.
•
•
•
•
•
Secton 4 - Hazards
Electrocution Hazard