Page 48
45-J Desel - Servce & Parts Manual
January 2022
Deutsch Connectors
Deutsch connectors used on MEC equipment are designed so that individual parts may be replaced
without replacing the entire component. Special tools and detailed instructions are provided in
Deutsch Connector field kits, MEC part no. 84091.
Male Plug Connector
Use the flat end of the Removal Tool or a flat blade
screwdriver to pry the Locking Wedge from the
connector, taking care not to damage the Sealing
Gasket.
Inspect and replace damaged parts.
Replace or re-crimp wires and contacts.
Female Receptacle Connector
Use the notched end of the Removal Tool or a wire
hook to pull the Locking Wedge from the connector.
Replace worn or damaged parts.
Replace or re-crimp wires and contacts.
Locking Fingers
Remove the Locking Wedge as outlined above.
Using the Removal Tool or a flat blade screwdriver,
push the Locking Fingers aside to release the
contact.
Pull the wire and contact out of the connector.
Heavy Duty Plug
Slide the Removal Tool along the wire to be replaced
and push into the connector to release the contact.
Pull the wire and contact out of the plug.
Crimping
Strip 1/4 in. (6 mm) insulation from the wire.
Insert the contact into the crimping tool and insert
the stripped wire into the contact making sure no
wires are outside the contact barrel.
Close the handles of the crimping tool, then release
the handles to remove the crimped contact.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
ART_2041
Deutsch Connector Field Kit
MEC part # 84091
Deutsch Connectors
Secton 14 - Deutsch Connectors