Page 100
65-J Desel - Servce & Parts Manual
February 2021
Secton 19 - Troubleshootng
Using The EZ-Cal With The Flow Charts
Use the EZ-Cal Flow Charts as a guide to locate diagnostic information and make adjustments. Each
box in the flow chart will have 3 bits of information.
UP MAX
75%
5C-2
Identification Number
Personality
Default Setting
to match with information tables, this number
will not appear on the EZ-Cal display
ART_3183
The IDENTIFIER (5c2):
Used to locate this specific personality in the informational charts. Here you
can obtain specific information on the individual personalities.
The PERSONALITY (Up Max):
Identifies the individual personalities.
The DEFAULT SETTING:
The factory setting. If adjustments are made, they must be returned to
default setting.
ACCESS LEVEL 1 PROVIDES ACCESS TO CHANGE PERSONALITIES
NORMALLY PRESET AT THE FACTORY TO PROVIDE PROPER MACHINE
MOVEMENT AT SAFE SPEEDS������ PERSONALITIES MUST NOT BE
CHANGED WITHOUT PRIOR AUTHORIZATION FROM MEC AND MAY
ONLY BE RETURNED TO FACTORY SPECIFICATION AS LISTED IN THE
FOLLOWING TABLES������
Error Messages
To obtain error messages from the EZ-Cal, access the EZ-Cal as mentioned above. The display will
read, “HELP:PRESS ENTER”. Press Enter to display the current error message. If an error message
is present, use the following list of error messages to better understand the fault. If an error message
is not present, the display will show the last operation performed.
Pressing Enter twice will provide a log of previous errors and operations that may have occurred
within recent operation. The first message will be the most recent.
Flash Codes
Flash Codes, provided from the GP400 red LED, will also assist in the event an EZ-Cal is not
available. However, the EZ-Cal yields considerably more relevant information. Refer to “EZ-Cal
Messages” on page 103 for flash coded error messages.