ELECTRICAL CONNECTIONS TO THE MOTOR
Remove the terminal board cover to access power supply terminals.
Cut out the cover as indicated to allow the gland of the power supply cable to pass through.
With Aproli 480 fitted with courtesy lamp, power supply terminals are positioned at the back.
ADJUSTING THRUST POWER
Aproli 480 is fitted with screws to control the pressure valves ie. the thrust power to open and close the door.
If the door has been properly balanced as explained before, no power adjustment is required.
English
Should the operator shaft rotate
in the opposite direction, swap
the live 10 and 12
230 V - 50 Hz
6 μF
230 V - 50 Hz
blue c
o
mmon
Liv
e
Liv
e
Power supply
terminal board
Cover
Cable gland
Power supply
terminal board
Elpro 6 exp
Elpro 6 exp
In case a start
capacitor is
needed
Red
screw: controls
power in
opening
Clockwise = + power
Anticlockwise = - power
Green
screw: controls
power in
closing
Clockwise = + power
Anticlockwise = - power
Aproli 480 locking
device activated
Pic. 16
Pic. 17
10 11 12
13 14
10
Oil-hydraulic operator for tilt-up doors with counterbalance
APROLI 480