electromechanical operator for sliding gates
Nyota 115 evo
20
ELECTRICAL CONNECTIONS TO THE MAGNETIC LIMIT SWITCH
NOTE WELL: rst of all identify the position of Nyota 115 evo in relation to the opening direction of the gate
view from inside (on the left or right). Depending on this, properly connect the brown and green wires of the
limit switch and the wires of the electric motor.
NOTE WELL: Nyota 115 evo in the version with incorporated Elpro 12 evo control board comes factory pre-wired
as if it were going to be installed on the
left
. In case Nyota 115 evo is required to be installed on the
right
,
right
right
swap the connections to terminals 8 - 10 and 16 - 18.
!
Magnetic
limit switch
sensor
Nyota 115 evo
mounted on the
left
Elpro 12 evo
Elpro 37
Elpro 37 DS
Elpro 37 FN
Elpro 12 evo
Elpro 37
Elpro 37 DS
Elpro 37 FN
Nyota 115 evo
installed on the
right
Magnetic
limit switch
sensor
Pic. 13
Pic. 14
MOUNT ON THE RIGHT
MOUNT ON THE LEFT
17
17
18
18
16
12/24 Vac/dc
8
10
12 13
!
12/24 Vac/dc
10
10
8
12 13
16 17
17
18
18
!
M
M