MPCIB 396 P6
mect s.r.l.
ME3025_13 03/21
13
n°
seq.
Key to
press
Appears
on the
display
NOTES
12
Reset
Exit
“measure” To get out from the menu
3.
If requested monodirectional input see paragraph “monodirectional pulse
counter functioning”
4.
If requested Add/Subtract counting modes see paragraph “A+B and A-B
functioning”
5.
If requested marker pulse see paragraph “marker pulse functioning”
6.
Set up the correcting factor using “nUnEr” and “dEnon” items (see paragraph).
7.
Set a preset number (if desired) using “PrESEt” function.
8.
Set alarms (if requested see paragraph)
9.
Set serial outputs (if requested see paragraph)
10.
Set analogue outputs (if requested see paragraph)
11.
Set, if desired, the programming menu access code (password function)
12.
For default parameters see "default parameters" paragraph
13.
The unit is now ready to be used.
Table 4
n seq.
Key to
press
Appears
on the
display
NOTES
1
prog.
PASS
Touch the “prog.
” key to get into the
programming menu
2
prog.
0 0000
Digit the personal Password. Press “prog.
“
to confirm. (see “Password function”)
3
OUtPUt
4
InPUt
5
prog.
nUnEr
MULTIPLAYING FACTOR
6
prog.
10000
Set multiplying factor value (1
65535). This
number will be the numerator of the correction
constant
** (press “prog.
” to confirm)
7
nUnEr
8
dEnOn
DIVISION FACTOR
9
prog.
10000
Set division factor value (1
65535). This number
will be the denominator of the correction constant
**(press “prog.
” to confirm)
10
dEnOn
11
PrESEt
PRESET SET UP