MPCIB 396 P6
mect s.r.l.
ME3025_13 03/21
14
n seq.
Key to
press
Appears
on the
display
NOTES
12
prog.
000000. Set up the desired preset between –999999 and +
999999
**(press “prog.
” to confirm)
13
PrESEt
14
nrES
RESET TERMINAL CONFIGURATION
15
prog.
StAt
StAt = the instrument remains at zero till when the
terminal is short-circuited
dIn = the instrument instantaneously zeroes itself
when the terminal is short-circuited
Press “
” key till when the desired function
appears on the display
**(press “prog.
” to confirm)
16
nrES
17
StorE
TOTAL COUNTING AND PARTIAL
COUNTING STORED AT THE SWITCHING
OFF
18
On
On =it memorizes the counting
OFF = it doesn’t memorize the counting
Press “
” key till when the desired function
appears on the display
**(press “prog.
” to confirm)
19
StorE
20
nInP
INPUT TERMINALS SELECTION
21
prog.
nPn
nPn =“reset” and “hold” inputs have NPN polarity
PnP = “reset” and “hold” inputs have PNP polarity
Press “
” key till when the desired function
appears on the display
**(press “prog.
” to confirm)
22
nInP
23
rEStot
TOTAL COUNTING ZEROING
24
prog.
OFF
On = it zeroes the total counting
OFF = it doesn’t zero the total counting
Press “
” key till when the desired function
appears on the display
**(press “prog.
” to confirm)
25
rEStot
26
CoEnC
ENCODER COUNTING
27
prog.
F 1
Press “
” key till when the desired function