2.6 “ PrESEt” FUNCTION (preset)
The “PrESEt” function on the MPCIB396 P6 instrument allows to set up a preset, i.e.
a number which appears every time that the instrument is zeroed.
The “PrESEt” function works with any number between –999999 and +999999 (to
set up the negative sign see “SET UP” paragraph). To set the visualization at the
“PrESEt” value, it is sufficient to press the reset front key (if enabled), or the
terminal reset. To modify this function see Table 4.
2.7 DEFAULT PARAMETERS (dEF)
Some wrong values in menu programming function can cause the “ERR” item to
appear. To reset to factory default parameters you can use the “dEF” function, which
sets up all the programmation parameters at the factory value, eliminating all the
error situation (look the following table).
BE CAREFUL: all previous programmed values will be lost.
Table 7
n°
seq.
touch
key
Appears
on the
display
NOTES
1
prog.
PASS
Press “prog.
” key to get into the programming
menu
2
prog.
0 0000
Digit the personal password
** (confirm with “prog.
”)
3
OUtPUt
4
InPUt
5
C.PASS
6
AbtASt
7
CnFnor
Terminal configuration if serial output are
requested
8
dEF
DEFAULT PARAMETERS
9
prog.
On
Touch the "
" key until the written “ON”
appears ** (confirm with “prog.
”)
The instrument exits from the programming menu
and it follows the default parameters.
2.8 TOTAL COUNTING FUNCTION
By the
key it is possible to visualize the total counting on the display. The total
counting is the sum of all the partial counting memorized after a reset. The total
count can be shown on display divided by the value programmed in the “dIUSOn”
menu item. The “In” led switching on means that the display is visualizing the total
counting. To zero this counting it is necessary to put “on” at the “rEStot” menu item