MPCIB 396 P6
mect s.r.l.
ME3025_13 03/21
23
Table 8
n°
seq.
Touch
key
Appears
on the
display
REMARKS
1
prog.
PASS
Touch the “prog.
” key to get into the
programming menu
2
prog.
0 000
Digit the password code
**(press “prog.
” to confirm)
3
OUtPUt
4
prog.
ALL
5
prog.
AL01
ALARM 1 PARAMETERS
6
prog.
tIPOAL
ALARM SELECTION
7
prog.
FInES
FinES = windowed alarm
S.StOP = alarm with stop counting
S.AUUP = automatic cycle alarm (count up)
S.AUdO = automatic cycle alarm (count down)
SOGLIA = threshold alarm
Select the desired item by "
" key and confirm with
“prog.
”
8
tIPOAL
9
rELE
AL1 CONTACT CONFIGURATION
10
prog.
nA
n.A. = relay normally open
n.C. = relay normally closed
Select the desired item by "
" key and confirm with
“prog.
”
11
rELE
12
SP 1
First trigger set point SET UP
13
prog.
0 00000
Set up the SP1 value. **(Confirm by “prog.
”)
14
SP 1
15
SP 2
Second trigger set point SET UP. Program only if the
functioning of the windowed alarm is requested.
16
prog.
0 00000
Set up the SP2 value. **(Confirm by “prog.
”)
17
SP 2
18
HY
HYSTERESIS ALARM 1 SET-UP
19
prog.
00 250
Set up a number between 0 and 250 digit.
** (press “prog.
” to confirm)
20
HY
21
SEL.d
TIME CONFIGURATION AL1
22
prog.
ECC
ECC = activation delay
dIS = deactivation delay