background image

16

Information on swing bolt lock installation

If you are using a swing bolt lock, skip steps 13 through 14 and continue at step 15. Steps 13 and 14 are not required.

Medeco XT

Safe Lock Installation Guide

12.  You should now insert any XT key into the installed Reader to perform a mechanical rotation test.

• Test clockwise rotation for proper free movement (102 degrees).

•  Ensure that the green, red and black wires in the Reader are not inhibited or restricted during

clockwise testing of rotation.

• Ensure there is no interference or inhibiting of the lock mechanism during rotation.

• If you installed the spindle, check for proper engagement and uninhibited movement.

13.  Locate the lock assembly, the three lock assembly screws and the spindle insert (if required).

FIGURE 10

Summary of Contents for EA-100206

Page 1: ...Medeco XT Intelligent Key System Medeco XT Safe Lock Installation Guide...

Page 2: ...e following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interferences that may cause undesired operation ASSA ABLO...

Page 3: ...ing Label Security Seal 5 What is Included in the Box 6 What Tools are Needed 7 Before you Begin 7 Installation Type 7 Installing your Medeco XT Safe Lock 8 Installation All Lock Bolt Configurations 8...

Page 4: ...Software Help link The Medeco XT Web Manager documentation provides instructions for overall system use including programming and scheduling of your XT keys accessing audit information and data analy...

Page 5: ...afe Lock Installation Guide Information on Scheduling the Medeco XT Key using the Control Key Type For a Medeco XT Safe Lock configured in the Time delay functional mode the Control key type provides...

Page 6: ...ck Reader Product Box Part Name Part Number Cable tie CP 284200 Cable tie mount EA 300221 Spindle CP 240880 Spindle insert CP 131260 Spindle adaptor EA 100216 Split bushing CP 160900 Hex key wrench 5...

Page 7: ...alling your XT Safe Lock you should familiarize yourself with these instructions and ensure that you have all the necessary parts and tools Installation Type The XT Safe Lock is available in three dif...

Page 8: ...nstalled Tip for Swing Bolt Lock Installation If you are using a swing bolt lock assembly complete steps 1 3 in this section and skip to the section titled Installation Swing Dead Spring Bolt Lock Con...

Page 9: ...install the split bushing in the spindle hole on the inside wall of the safe door 4 Locate the spindle insert and lock assembly 5 See Figure 2 for proper alignment of spindle insert Warning Security S...

Page 10: ...rtant to distinguish the double D or 2 flat sides end of the spindle from the single D end 1 side flat Medeco XT Safe Lock Installation Guide 9 From the outside wall of the safe door insert the double...

Page 11: ...Remove any burs and smooth down any rough spots along the cut edge of the spindle with your file 13 The spindle length has now been adjusted Now you are ready to install the spindle adaptor 14 Locate...

Page 12: ...ixed to the lock assembly case or if the seal is damaged or broken you should not install the lock but instead contact your dealer Medeco XT Safe Lock Installation Guide 17 Remove the lock assembly yo...

Page 13: ...The drive pins on the spindle adaptor have different diameters and must be placed in the corresponding sized holes on the back of the Reader assembly Medeco XT Safe Lock Installation Guide 4 If you a...

Page 14: ...s at the back of the Reader assembly with the two slots in the escutcheon to properly insert the Reader into the escutcheon as shown in Figure 8 8 Attach the Reader and escutcheon to the mounting plat...

Page 15: ...tor Take care not to separate the spindle adaptor and spindle assembly from the Reader port plug if required 10 Locate the split bushing 11 On the inside of the safe door insert the split bushing into...

Page 16: ...echanical rotation test Test clockwise rotation for proper free movement 102 degrees Ensure that the green red and black wires in the Reader are not inhibited or restricted during clockwise testing of...

Page 17: ...Reader inner housing orienting it according to the polarity indicators shown above in Figure 9 Information on the location of the spare screw A spare 2 56x1 4 flat head hex socket screw is located in...

Page 18: ...050 hex key wrench install the 2 56x1 4 flat head hex socket screw upwards into the lower end of the outer housing in order to fasten the outer housing to the inner housing 25 Locate the cable tie an...