16
Information on swing bolt lock installation
If you are using a swing bolt lock, skip steps 13 through 14 and continue at step 15. Steps 13 and 14 are not required.
Medeco XT
Safe Lock Installation Guide
12. You should now insert any XT key into the installed Reader to perform a mechanical rotation test.
• Test clockwise rotation for proper free movement (102 degrees).
• Ensure that the green, red and black wires in the Reader are not inhibited or restricted during
clockwise testing of rotation.
• Ensure there is no interference or inhibiting of the lock mechanism during rotation.
• If you installed the spindle, check for proper engagement and uninhibited movement.
13. Locate the lock assembly, the three lock assembly screws and the spindle insert (if required).
FIGURE 10