Quick guide P9-0291-Q
9 of 16
Version 1.0.0/2011
Medema Production A/S
Safety check
Daily safety check:
The electronic system has an integrated safety check which runs up to
100 times per minute. To supplement this check, you should carry out the
following regular checks.
•
Switch off the electronic system (no lights in the display)
•
Check if the joystick is bent
•
Check if the joystick is damaged in any other way
•
Check that it returns to the central position when you release it
If the check reveals any problems, contact a competent service engineer
before using the scooter again.
Weekly safety check:
Parking brake: This test must be carried out on a fl at surface with at least
one metre of free space around the scooter.
•
Start the scooter and slowly move the joystick forward. There is a
clicking sound. (The scooter may start to move in this setting).
•
Immediately release the joystick and listen for the clicking sound, which
should occur within one second.
Repeat in all directions.
•
Check that the rubber bellows around the joystick is intact. This is
important, as the bellows prevent moisture getting into the electronic
system.
•
Check that the control box is properly secured.
If the check reveals any problems, contact a competent service engineer
before using the scooter again.