background image

Customer Service 1-888-707-1880 

 

                                                                               

Dyaco Canada Inc. 2015

                 

Email: 

customerservice@dyaco.ca

 

13 

key. You can also go back and modify your settings by pressing the Enter key. NOTE: At any 
time during the editing of Data you can press the Stop key to go back one level, or screen. 

5.  During the Manual program you will be able to scroll through the data in the message 

window by pressing the 

Display key

. You may also switch between the profile or power 

displays and a quarter mile track by pressing the Display key adjacent to the dot matrix 
display.   

6.  When the program ends you may press Start to begin the same program again or Stop to 

exit the program, or you can save the program you just completed as the 

Facility 

program 

by pressing the Facility key and following the instructions in the message window. 

 

Facility Program 

 

 

The Facility program allows you to build and save a custom program. You can build your own 
custom program by following the instructions below or you can save any other preset program you 
complete as a custom program. The Facility program allows you to further personalize it by adding 
your facility name.   

 

Designing and saving a new program: 

1.  Press the 

Facility

 key. The message window will show a welcome message; if you had 

previously saved a program the message will contain the name you gave it. Then press the 

Enter

 key to begin programming.   

2.  When you press enter, the message window will show “Name – A”, if there is no name saved. 

If the name “Custom Workout” had been previously saved the message window will show 
“Name – Custom Workout” and the C in Custom will be blinking. If there is a name saved you 
can change it or you may press the Stop key to keep the name and continue to the next step. 
If you want to enter a name use the Up and/or the Down key to change the first letter then 
press Enter to save the first letter and continue to the next letter. When you have finished 
entering the name press the Stop key to save the name and continue to the next step. 

3.  The message window will ask you to enter an 

Age

. You may enter an Age, using the Up and 

Down keys or the numeric key pad, then press the Enter key to accept the new number and 
proceed on to the next screen.   

4.  You are now asked to enter a 

Weight

. You may adjust the Weight number using the Up and 

Down keys or the numeric key pad then press enter to continue. 

5.  Next is 

Time

. You may adjust the Time and press enter to continue. 

6.  Now you are asked to adjust the 

Max Level.

 This is the peak exertion level you will 

experience during the program. Adjust the level and then press enter.   

7.  Now the first column will be blinking and you are asked to adjust the level for the first 

segment of the workout. When you finish adjusting the first segment, or if you don’t want to 
change, then press enter to continue to the next segment. 

8.  The next segment will show the same level as the previously adjusted segment. Repeat the 

same process as the last segment then press enter. Continue this process until all twenty 
four segments have been set. 

9.  The message window will then tell you to press enter to save the program. After saving the 

program the message window says “New program saved” then will give you the option to 
Start or modify the program. Pressing Stop will exit to the start up screen. 

10. During the Facility program you will be able to scroll through the data in the message window 

by pressing the adjacent 

Display 

key. 

 

 
Running a saved program: 

1. 

Press Facility key then Enter 

2. 

Enter Time then set Auto-brake on or off and press enter. Then press start to begin 

program.

 

Summary of Contents for Spirit MR100

Page 1: ...MR100 Rehabilitation Recumbent Bike USER S MANUAL PLEASE READ THIS ENTIRE MANUAL CAREFULLY BEFORE OPERATING YOUR NEW LOWER BODY ERGOMETER AND SAVE IT FOR FUTURE USE...

Page 2: ...rtant Electrical Information 4 Important Operation Instructions 4 Features 6 Operation of Your New Bike 8 MR100 Assembly Instructions 21 MR100 Exploded View Drawing 31 MR100 Parts List 32 Maintenance...

Page 3: ...rience more informed and resolution of any difficulties easier to remedy Two components of the Spirit Medical Systems Group s mission statement are enhancing patient outcomes and improving effectivene...

Page 4: ...l devices Various factors including the user s movement may affect the accuracy of heart rate readings The pulse sensors are intended only as exercise aids in determining heart rate trends in general...

Page 5: ...n equipment grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances DANGER Improper connection of t...

Page 6: ...dback display motivates patients to maintain even power symmetry between left and right legs Other features of the MR100 Work range up to 750 watts 60 rpm when level settings are at 15 watts per level...

Page 7: ...asy product to set up and use from the adjustments to the intuitive interface This section explains how to set up adjust and operate your MR100 from Spirit Medical Systems Group Leveling the MR100 Onc...

Page 8: ...n the right side handle bar and move the seat back to the desired position There is a numbered scale located just below the seat back cushion for repeatable settings Rotating the swivel seat Lift the...

Page 9: ...he display will look like this ODO 123 MI 123 HRS The odometer will remain displayed for only a few seconds then the console will go to the start up display also known as Idle Mode The dot matrix disp...

Page 10: ...osition is assumed to be in the center of the adjustment range The six knee angle options are 1 R Min Right leg minimum flexion L Min Left leg minimum flexion 2 R Max Right leg maximum flexion L Max L...

Page 11: ...uctions and relevant measurements during a program The measurement data shown varies depending on the program Measurements include Time and Segment Time RPM Pulse Work level Watts and Average Watts Le...

Page 12: ...press the Stop key to go back one level or screen 5 During the Manual program you will be able to scroll through the data in the message window by pressing the Display key You may also switch between...

Page 13: ...by depleting your oxygen level followed by periods of recovery to replenish oxygen Your cardio vascular system gets programmed to use oxygen more efficiently this way Programming Preset Programs 1 Se...

Page 14: ...name and continue to the next step If you want to enter a name use the Up and or the Down key to change the first letter then press Enter to save the first letter and continue to the next letter When...

Page 15: ...protocol will be used during the test as shown in the charts below The only caveat is if you are a very de conditioned male you may need to choose option Female If you are a very conditioned female yo...

Page 16: ...eine before the test During the test The console must be receiving a steady heart rate for the test to begin You may use the hand pulse sensors or wear a heart rate chest strap transmitter although ch...

Page 17: ...46 40 42 35 38 32 35 30 31 26 28 below average 37 41 35 39 31 34 29 31 26 29 22 25 poor 30 36 30 34 26 30 25 28 22 25 20 21 very poor 30 30 26 25 22 20 VO2max Chart for females and de conditioned male...

Page 18: ...the instructions in the message window Isokinetic The Isokinetic program provides accommodating resistance at a fixed speed level The user controls the resistance at the pedals by pushing harder or l...

Page 19: ...ify your settings by pressing the Enter key For Best Results The Symmetry program starts at level 1 and the resistance needs to be increased manually by pressing the Up arrow Make sure to set the resi...

Page 20: ...le to maintain good strong reliable readings Wearing the transmitter immediately against bare skin assures you of proper operation If you wish you may wear the transmitter over a shirt To do so moiste...

Page 21: ...e Heart rate Level This is the heart rate level you will experience during the program Adjust the level and then press enter 6 Now you are finished editing the settings and can begin your workout by p...

Page 22: ...ada Inc 2015 Email customerservice dyaco ca 21 ASSEMBLY INSTRUCTIONS FOR MR100 1 Hardware 65 3 8 2 1 4 4PCS 71 3 8 2 4PCS 175 3 8 2 3 4 2PCS 208 5 16 1 1 4 1PC STEP 1 77 3 8 3 4 6PCS 84 3 8 1 4PCS 205...

Page 23: ...vice 1 888 707 1880 Dyaco Canada Inc 2015 Email customerservice dyaco ca 22 STEP 2 216 M6 P1 0 2PCS 221 M6 P1 0 40L 2PCS 83 5 16 3 4 4PCS STEP 3 136 M5 20L 4PCS 220 3 8 1 3 4 2PCS 215 3 8 2PCS 206 10m...

Page 24: ...ice 1 888 707 1880 Dyaco Canada Inc 2015 Email customerservice dyaco ca 23 STEP 4 68 5 16 5 8 8PCS 82 5 16 2PCS 76 5 16 3 4 6PCS 83 5 16 3 4 2PCS 187 M4 5L 4PCS 98 M6 15L 2PCS STEP 5 99 M5 12L 8PCS 22...

Page 25: ...Service 1 888 707 1880 Dyaco Canada Inc 2015 Email customerservice dyaco ca 24 2 Tools 112 12 14m m Open wrench 1PC 114 Phillips Head Screw Driver 1PC 132 14 15m m Open wrench 1PC 200 5m m L Allen Wr...

Page 26: ...r Service 1 888 707 1880 Dyaco Canada Inc 2015 Email customerservice dyaco ca 25 283 8m m L Allen Wrench 1PC 201 Short Phillips Head Screw Driver 1PC 284 13 14m m Open wrench 1PC 280 10m m Wrench_sing...

Page 27: ...eceiving tubes of the seat frame 38 Secure the handle bar assembly starting with the two 3 8 x 2 3 4 bolts 175 install from the inside hole of the receiving tube two flat washers 77 and nuts 89 Do not...

Page 28: ...ail customerservice dyaco ca 27 STEP 2 SWIVEL SEAT RELEASE HANDLE ASSEMBLY 1 Install the swivel seat release handle 40 onto the mating flat area of the solid round bars and secure with the two M6 x 40...

Page 29: ...STEP 3 SEAT BACK AND COVER ASSEMBLY 1 Slide the seat back assembly 5 into the seat back angle adjustment bracket and secure with the two 3 8 x 1 3 4 bolts 220 3 8 washers 206 and 3 8 nuts 215 2 Insta...

Page 30: ...d gently keeping tension on the cables at the top of the mast with the other install the Console Mast 2 into the Main Frame receiving tube under the cover 31 Keeping tension on the cables will ensure...

Page 31: ...d right 117 pedals onto the crank arms Remember that the left pedal has a reverse thread and will be screwed into the crank in the opposite rotation from normal threads There is an L stamped into the...

Page 32: ...Customer Service 1 888 707 1880 Dyaco Canada Inc 2015 Email customerservice dyaco ca 31 MR100 Exploded View Drawing...

Page 33: ...60067 R4 Seat Assembly Stop 2 17 P060256 A1 Rubber Foot Leveler 2 18 P050014 A1 Transportation Wheel 2 19 ZSB006 02 Console Assembly 1 20 RP060090E A1 Drive Pulley 1 21 F090250 01 Hand pulse Sensor W...

Page 34: ...8 Z1 3 8 2 Hex Head Bolt 4 72 J210016 Z1 1 4 1 2 Flat Washer 5 73 J210017 Z1 1 4 x 3 4 Flat Washer 4 76 J210005 Z1 5 16 3 4 Flat Washer 6 77 J210003 Z1 3 8 3 4 Flat Washer 8 78 J210020 Z1 3 16 19 32 F...

Page 35: ...4 Z1 M5 20mm Phillips Head Screw 4 141 P060191 A1 Handle Bar Cover 1 143 B020003 Z3 Seat Position Scale For Aft 1 148 P280004 A1 Dummy Plug 1 160 J210032 Z1 5 16 5 8 Flat Washer 6 161 J602501 Y9 M6 10...

Page 36: ...Z1 3 8 UNC16 7T mm Nyloc Nut 2 216 J139601 Z1 M6 P1 0 Nylon Nut 2 217 J139311 Z1 M12 P1 75 Nylon Nut 1 220 J031007U Z1 3 8 UNC16 1 3 4 Socket Head Cap Bolt 2 221 J032508W Z1 M6 P1 0 40 mm Socket Head...

Page 37: ...0m m Hand Pulse Extension Cable 1 274 E030401 01 800m m Hand Pulse Wire 1 275 B130227 R4 Cover Mech Brake 2 276 J082514 Z1 M6 P1 0 57L Eye Bolt 1 277 J210063 Z1 1 2 26 2 0T mm Flat Washer 1 278 RC1200...

Page 38: ...Customer Service 1 888 707 1880 Dyaco Canada Inc 2015 Email customerservice dyaco ca 37 299 P040071 A1 HGP Wire Grommet 2 300 J260008 Z2 Split Washer 2 301 E040200 Ground Wire 450mm 14AWG 1...

Page 39: ...nd hold down the Start Stop and Enter keys Keep holding the keys down for about 5 seconds and the message window will display Engineering mode Press the enter button to access the menu below a Key tes...

Page 40: ...45cm Width 30 77cm Height 51 130cm Weight 185 9 lbs 84 5 kg Patient weight capacity 440 lb 200 kg Power 90 240V 50 60 Hz 1 76 0 71A Fuse Rating Replace with only 5A 250V glass fuse Resistance Constant...

Page 41: ...turer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in...

Page 42: ...01 test level Compliance level Electromagnetic environment guidance Electrical fast transient burst IEC 61000 4 4 2 kV for power supply lines 1 kV for input output lines 2 kV for power supply lines 1...

Page 43: ...rranty provided herein is lieu of all other express warranties any implied warranties including any implied warranties of merchantability of fitness for particular purpose are limited in duration to t...

Page 44: ...tion about our other brands and products manufactured and distributed by Dyaco Canada Inc www spiritfitnesscanada ca www dyaco ca www spiritfitnesscanada ca www dyaco ca www solefitness ca www dyaco c...

Reviews: