Model No.
Description
Power Suplly
Static Power Consumption
Sensing Range
GAJ002AC
Automatic faucet with soap dispenser
DC:6V(4AA alkaline batteries
)
AC
:
220V-240V
;
50/60Hz
DC:≤0.18-0.33mW
Sensing for water
:
25±5CM
(based on white board)
Sensing for soap
:
10±2CM
(based on white board)
Water Pressure
Ambient Temperature
Inlet
0.5Bar-8 Bar
1
℃
-55
℃
G1/2”
Trouble shooting
Specifications
Symptom
Cause
The battery is exhausted
Water supply cut off
No water out
Dirt in the filter
Water pressure too low
There is still air in the soap tube
No soap out
Treatment
Change the battery
Check supply
Clean the filter
Raise the pressure
Sense the soap sensor
repeatedly until soap out
Too low ambient temperature,
Fill in proper amount of warm
the soap is easy to freeze
water (approximate 60
℃
)
The soap in the bottle is too little
Fill more soap
The check valve is blocked
Replace the check valve
Water or soap
will not turn off
Dirt on the sensor window
Clean the sensor
Water supply is turned down
Adjust water supply
Too little
water flow
The filter is too dirty
clean the filter
Water pressure is too low
Raise the pressure
Too much
water flow
Short cycles
of battery
Water pressure is too high
Adjust pressure
Incorrect batteries
The light is broken
Change to 4AA
Alkaline batteries
Change the light or
circuit board
The indicator
light is
The circuit board is wet or signal
line is wet
The battery is exhausted
Poor connection of battery
Dry out
Change the battery
Check battery connections