IMPORTANT SAFETY INSTRUCTIONS:

IN ORDER TO AVOID ANY DAMAGE TO YOU, OTHERS OR PROPERTY, FOLLOW THE FOLLOWING SAFETY PRECAUTIONS:

IF THE POWER CORD OR UNIT DOES NOT WORK, CONTACT MEDIFY CUSTOMER SERVICE IMMEDIATELY.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING – 

TO REDUCE THE RISK OF BURNS, FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS:

•  To reduce the risk of fire or electrical shock, DO NOT use this fan with any solid-state speed control device.
•  This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electrical shock, this plug 

is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still 
does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.

•  DO NOT touch power plug with wet hands.  Wet hands can cause an electrical shock to occur. Never touch with wet hands.
•  Turn off the power before cleaning machine.  Unplug before cleaning to avoid electrical shock or unit turning on accidentally.
•  DO NOT take apart or modify unit without authorization.  Taking apart or modifying it without authorization may cause 

personal injury or unit malfunction.

•  DO NOT put bars or metal products nearby air outlet or openings.  If metal bars touch inside of machine it can cause electrical shock.
•  DO NOT damage power line and socket.  Do not bind wires when you use the unit. It may cause electrical shock, short 

circuit, or fire if you use broken wires.  Forbidden to cut, scratch, refit, distort, twist or pull power lines. DO NOT put any 
heavy products on top of wires or sockets.

•  Regularly clean power plug.  Do not allow dust to accumulate on power plug. This can damage insulation and cause a 

fire accident to happen. Pull out the power plug and clean with dry cloth (do not use a wet cloth). If you are not planning 
to be used this machine for any extended period of time, unplug it for safety reasons.

•  Prohibited use beyond power. Can only use a 220v unit with a 220v power supply. Can only use a 110v unit with a 110v 

power supply. You can break or ruin the circuit boards if you plug a 110v plug into a 220v power supply. 

•  Please insert the plug completely into the power socket before starting the unit. If not, this may cause an electrical 

shock and overheating, or even a fire accident to occur.  Do not use damaged plug or loose socket.

•  Keep machine dry. Or else it may cause an electrical shock or a fire accident to happen.
•  Keep machine away from volatile substances or flammable items. This could cause a fire.
•  DO NOT use unit in greasy area. This machine should not be used as ventilating or air evacuating equipment.
•  DO NOT use unit in high temperature or humid conditions. These situations may cause current damage, electrical 

shock, or even a fire accident to happen.

•  DO NOT use the unit in the room with fumigation type pesticides. Chemical residue could be accumulated inside the 

machine and then released, causing harm. The room should keep ventilated thoroughly after you use insecticide and 
then start to use air purifier.

•  If you use the unit in a room with an electric heater, ensure proper ventilation. Otherwise, there could be a buildup of carbon 

monoxide, which can cause serious harm or death.  The air purifier will NOT remove carbon monoxide from the air.

•  DO NOT use solvents like  benzene, diluent, etc. to clean  the air purifier. This can cause the unit to break, to become 

damaged, or short circuit, which can lead to an electrical shock or even a fire accidents to happen.

•  Be careful when removing the plug from the power socket. DO NOT pull wires which may cause short circuit or damage 

to wires, to avoid possible fire accident or electrical shock.

•  BEFORE USING THIS PRODUCT, PLEASE MAKE SURE TO REMOVE THE PLASTIC COVERING FROM ALL FILTERS.

SAVE THESE IMPORTANT INSTRUCTIONS FOR EASY REFERENCE.

Summary of Contents for MA-22

Page 1: ...MA 22 AIRPURIFIER READ AND SAVE THESE INSTRUCTIONS INSTRUCTION MANUAL AND WARRANTY INFORMATION Lifetime warranty if replacing filters on time MA 22 US Rev 10 12 21 ...

Page 2: ... are not planning to be used this machine for any extended period of time unplug it for safety reasons Prohibited use beyond power Can only use a 220v unit with a 220v power supply Can only use a 110v unit with a 110v power supply You can break or ruin the circuit boards if you plug a 110v plug into a 220v power supply Please insert the plug completely into the power socket before starting the uni...

Page 3: ...rms pet dander odor mold spores and smoke from air that passes through the filter CARBON ODOR FILTRATION Reduces household odors and VOCs volatile organic compounds gases as shown by independent laboratory testing PRE FILTER Captures large particles 3 SPEEDS Low medium and high speeds BUILT IN TIMER Choose from 1 2 4 or 8 hours REPLACE FILTER INDICATOR Illuminates when it is time to replace the fi...

Page 4: ...38 W Noise level 53 dB A Room size up to 140 sq ft Unit dimensions Ø8 07 H x 12 2 Unit weight 5 2 lbs EPA Est 87627 CHN 001 AIR PURIFER BASE FILTER STANDARD COVERAGE Up to 660 sf every 60 minutes up to 330 sf every 30 minutes 165 sq ft every 15 minutes ...

Page 5: ...hes pollen dust mites and other tiny airborne particles you can t see 3 ACTIVATED CARBON FILTER Substantial carbon filter with carbon pellets removes toxic odors smoke and formaldehyde To purchase genuine Medify replacement filters visit www medifyair com PREFILTER catches large particles like hair and dust TRUE HEPA H13 FILTER catches 99 9 of particles to 0 1 microns including pet dander and poll...

Page 6: ...on the unit will turn onto Speed 1 CONTROL FAN SPEED Press above button to select speed from the following options S 1 2 3 Speed 1 is slow speed Speed 2 is medium speed Speed 3 is fast speed S is Sleep mode STANDBY MODE Insert the plug of unit into a power source Unit lights will turn on After one second air purifier is in standby mode TIMER Timer set to 1H 2H 4H 8H CHILD LOCK FUNCTION Child Lock ...

Page 7: ...fier s hours of use INSTALLING FILTER SET All filters must be used together Please disassemble filters according to the following instructions Reinstall the filters accordingly 1 Place the machine in a dry location on a flat surface 2 Rotate the base clockwise 3 Pull the base downwards to reveal the filters Take out the filter to clean or replace with a new one ...

Page 8: ...in Figure A To secure the base rotate it counter clockwise as shown in Figure B Remove all plastic packaging from the filter before installing it DO NOT run the air purifier if there is no filter installed Please be careful when installing the back cover Watch your hands ATTENTION To purchase genuine Medify replacement filters visit www medifyair com ...

Page 9: ...r purifier regularly to prevent the dust accumulation 1 Use soft and dry cloth to remove the dust from the air purifier 2 Use soft and dry cloth to clean the outlet and inlet of the air purifier FILTER REPLACEMENT LIGHT INDICATOR TO REPLACE THE FILTER The unit will remind the user when the filter needs to be replaced The filter indicator light will let you know when you have reached that time Sugg...

Page 10: ...filter Motor is loose Contact customer service Performance issues The filter needs to be replaced Replace the filter with genuine Medify Air replacement filters for the best performance Air intake or outlet blocked Contact customer service Filter plastic not removed Remove packaging and then use Not enough space surrounding the air purifier Ensure 20 in distance between two sides of air intake and...

Page 11: ...er 30 days Medify Air s obligation and liability under this Lifetime Warranty is dependent on your use of our genuine filters purchased on our website or from our authorized resellers which can be found on our website Prohibited use beyond power Can only use a 220v unit with a 220v power supply Can only use a 110v unit with a 110v power supply You can break or ruin the circuit boards if you plug a...