PCF Pro User Manual
DOC01851
Page 14 of 74
Caution – Possible Equipment Damage
Caution
•
Never place items or person(s) on the lid, this is particularly important while
operating the carrier lift.
•
Ensure the thumb ball latches in the down position before moving the carrier
lift.
•
Never place items on the machine which could obstruct the lid from closing.
•
Never attempt to obstruct the lid from closing.
•
All baskets must be fitted when running a cycle.
•
Do not place items directly into the wash tank or allow them to make contact
with the tank sides.
•
Never scratch chamber walls. This can increase cavitation erosion.
•
Do not load basket with instruments pointing at the lid.
•
Do not overload the basket, maximum load of 10kg (22lbs) per basket.
•
Do not allow Luer pipes to protrude from the basket.
•
Always use a Full DIN Tray Standard to hold instruments (M20044).
•
When choosing a detergent, select one with a low chloride content.
Detergents with a high chloride content can be harmful to stainless steel.
•
Repeated fuse blows or circuit breaker trips indicate a short circuit or overload.
Have a fully trained technician locate and correct situation.
•
Use nonabrasive cleaners when cleaning unit. Follow directions on container
and rub in a back-and forth motion, in same direction as surface grain.
Abrasive cleaners damage stainless steel. Cleaner rubbed in a circular motion
or applied with a wire brush or steel wool will scratch and dull stainless steel.
•
Avoid running equipment into the Control Panel or Touch Screen to prevent
damage to controls.
•
When removing baskets always tilt down to ensuring any retained water drips
into the tank.
Caution – Chemical
Caution
•
Chemical bottles must be connected to the correct port. Otherwise, wash
efficiency and/or rinsing will be compromised. Ensure that the chemical type
matches the port shown on the display.
•
Check chemical bottles are in date before use
Caution – Instrument Care
Caution
•
Always confirm compatibility with the instrument manufacturer.
•
Always follow the manufacturer’s instructions if processing instruments with
special characteristics e.g. fibre optics or rigid optics.
•
Whether pre or post processing instruments, always follow the manufacturer’s
instructions.
•
Always attach tubing to a suitable size distal connector for instruments being
cleaned or to a quick connect port if the instrument has one.
•
Always open box jointed instruments.
•
Always ensure taps are open on cannulated instruments.
•
Always dissemble instruments that are designed to be taken apart.
•
Visually inspect instruments after reprocessing
•
If any instruments became detached from the Medisafe connection tubing
during processing, they should be reprocessed after ensuring that the Luer
connection is firmly seated.
Summary of Contents for PCF Pro
Page 1: ...DOC01851 PCF Pro User Manual...
Page 7: ...DOC01851 Page 7 of 74 1 Introduction 1 Introduction User Manual...
Page 19: ...DOC01851 Page 19 of 74 2 Installation 2 Installation User Manual...
Page 26: ...PCF Pro User Manual DOC01851 Page 26 of 74 Installation Drawings Rear View Showing Services...
Page 27: ...PCF Pro User Manual DOC01851 Page 27 of 74 Front View...
Page 29: ...PCF Pro User Manual DOC01851 Page 29 of 74 Left Side View Lid Open...
Page 31: ...DOC01851 Page 31 of 74 3 Operation 3 Operation User Manual...
Page 55: ...DOC01851 Page 55 of 74 4 Troubleshooting 4 Troubleshooting User Manual...
Page 59: ...DOC01851 Page 59 of 74 5 Technical 5 Technical User Manual...
Page 65: ...DOC01851 Page 65 of 74 6 Appendices 6 Appendices User Manual...