33
Blink Indication Follow-up Procedures
Blinking Green - System healthy, machine
should be operating on programmed run
schedule. If not operating on programmed
run schedule, contact Medora Corp. Customer
Service.
1X Blinking Yellow - High motor current, check
the machine for plugging at impeller and/or
strainer-intake.
2X Blinking Yellow - Low battery voltage,
machine may be operating at reduced speed or
temporarily shut down due to cloudy weather
period. Re-check machine after sunlight
conditions improve.
5X Blinking Yellow - Check GPS connection
at Brain-Board (lower right corner). If properly
connected and blink code persists, contact
Medora Corp. Customer Service.
1X Blinking Red - Anti-Jam Routine, machine is
operating on a jam removal sequence triggered
by high current. Check for plugging only after
disconnecting power. If power is not removed
first, machine may begin to operate
2X Blinking Red - 36 VDC out of range,
machine may be shut down due to blown fuse
(glass cylindrical) on the Zahn Board. Left
side of Zahn board takes a 5 Amp Fuse, Right
side of Zahn board takes a 20 Amp Fuse.
Disconnect power before changing fuses.
Blown fuses may be difficult to observe, so a
continuity tester or new fuse should be used to
confirm that the problem is not a blown fuse.
If your SolarBee has a fuse switch (20 Amp),
check that fuse also.
5X Blinking Red - Battery out of range,
machine battery is too low. Check and record
battery voltage if possible, then contact Medora
Corp. Customer Service.
For all other blink codes, please contact Medora
Corp.Customer Service.
SolarBee Troubleshooting
BRAINBOARD
ZAHN BOARD
Blinking LED’s
RED
YELLOW
GREEN
Solid LED
GREEN
GPS
SD Card
Slot
BRAINBOARD LED
BEHAVIOR
VISUAL
INDICATION
BLINKING GREEN
HEALTHY SYSTEM
SOLID GREEN, YELLOW,
HARDWARE ERROR
AND/OR RED
GREEN, YELLOW,
HARDWARE ERROR
AND RED OFF
SOLID BLUE
SD CARD INSERTED
BLINKS IN SUCCESSION
SINGLE BLINK RED,
CUSTOMIZED
YELLOW, AND GREEN
SYSTEM BOOT UP
ONE (1) RED BLINK
ANTI-JAM ROUTINE
TWO (2) RED BLINKS
36 VDC OUT OF RANGE
THREE (3) RED BLINKS
MOTOR COMM ERROR
FOUR (4) RED BLINKS
CHARGE COMM ERROR
FIVE (5) RED BLINKS
BATTERY OUT OF RANGE
ONE (1) YELLOW BLINK
HIGH MOTOR CURRENT
TWO (2) YELLOW BLINKS
LOW BATTERY VOLTAGE
THREE (3) YELLOW BLINKS
TEMP OUT OF RANGE
FOUR (4) YELLOW BLINKS
5 VDC OUT OF RANGE
FIVE (5) YELLOW BLINKS
GPS COMM ERROR
10 BLINKS, RED, YELLOW,
INCOMPLETE SD
AND GREEN SIMULTANEOUSLY
CARD UPDATE
ONE (1) YELLOW AND
GPS SATELLITE
GREEN SIMULTANEOUSLY
LOCK ERROR
ZAHN BOARD LED
BEHAVIOR
VISUAL
INDICATION
SOLID GREEN LIT
12 VDC ON
SOLID GREEN NOT LIT
12 VDC OFF
BLUE
Brain Board
Serial Number
Charging Circuit: 12VDC
Motor Power Circuit: 36VDC, 7A max
CUSTOMER SERVICE:
1-866-437-8076
5 Amp Fuse
20 Amp Fuse
DIGITAL
CONTROLLER
ON / OFF
SWITCH