Congratulations 

Your MedRx system is now set up and ready for use. Please consult the Training Manual and the 

Interactive Help Files within the software for instructions and procedures. The Training Manual is 

available in PDF format on a USB flash drive and at 

www.medrx

-int.com in our Download Section. 

 
Limited Warranty

 

MedRx warrants this product to be free from defects in material and workmanship for two years from 

the time of purchase. If this system fails to perform as specified during this period, the purchaser is 

responsible for calling MedRx at +49 30 70 71 46 43. The company's representative will advise the 

owner to either return specific components or the entire system to:   

MAICO Diagnostics GmbH 

MedRx International TCS 
Sickingenstr. 70-71 

10553 Berlin 

Germany  

MAICO will repair or replace any defective devices, fully test the system and/or components and ship 

the system promptly back to the owner. There is no cost for the repair or return shipping, provided 

the system is two years old or less and has not been misused, abused or damaged. Such damage 
includes, but is not limited to, dropping, exposure to excessive heat greater than 37,78º C and 

water/liquid damage.   

Repair or replacement of the system as provided under this warranty is the sole and exclusive remedy 
of the purchaser. MedRx shall not be liable for any consequential or incidental damages or for breach 

of any express or implied warranty. Except to the extent of applicable law, any implied warranty, 

merchantability or fitness of this product is limited to the duration of this warranty.   

MAICO will, at its discretion, service and repair out of warranty products at the purchaser's request, 

charging for parts and labor as necessary. The limited warranty is deemed void if software or 

hardware is installed on this product which is not pre-approved by MedRx, Inc. Approved software 

includes NOAH™ and HIMSA approved hearing aid manufacturer programming modules for fitting 

hearing aids.    

MAICO is not responsible for problems resulting from installation of unapproved software or 
hardware. In the event of unapproved software or hardware installed on the system causing a 

conflict, MedRx will service the product for a fee to be determined at the time of service.

 

 

Summary of Contents for AVANT AIR PLUS

Page 1: ...www medrx int com MANUAL INSTALLATION AVANT AIR AScreening Audiometer...

Page 2: ...Cleaning 17 Limited Warranty 18 www medrx int com Manufacturer MedRx Inc 1200 Starkey Rd 105 Largo FL 33771 U S A Toll Free 888 392 1234 727 584 9600 Fax 727 584 9602 E mail medrx medrx usa com www me...

Page 3: ...or training in the field of audiometry Indication for Use Statement This device is an audiometer For use by professionals with education and or training in the field of audiometry to conduct diagnost...

Page 4: ...M 5 GB free hard drive space Available 2 0 USB port Windows 7 or 8 Professional 32 or 64 bit MedRx Recommended Computer Specs Windows PC compatible computer Intel Dual Core 2 0 GHz or better 3 GB RAM...

Page 5: ...MTINI 1 Avant AIR Installation Manual 5 Effective Date 12 08 2017 Avant AIR Bottom View with Connectors Transducers and Accessories Talkback Mic Patient Response Switch Operator Mic and Monitor may va...

Page 6: ...vary depending on the USB port selected Consult your computer s documentation 2 Double Click on Setup to launch If requested Accept Permission to Install Software 3 On the Setup screen choose Install...

Page 7: ...Agreement select I accept click Next 6 This screen sets the language and location choice Make a selection and click Next 7 This screen indicates the location of the program files The default location...

Page 8: ...nt AIR Installation Manual Effective Date 12 08 2017 8 Installation of Program is ready to start To continue click Install To make changes click Back 9 Installation is in process 10 When the installat...

Page 9: ...Windows drivers When this screen appears and all devices are Ready to use click Close Next you need to confirm or set the Default Windows sound card settings This will route all non AVANTTM Windows so...

Page 10: ...specific Avant Audiometer will appear in both Output and Input Device Tab Click Audio Properties In Windows Sound control panel make sure the MedRx Audio Device is not set as default If it is default...

Page 11: ...ng Calibration Files Each Avant AIR is calibrated in compliance with the ANSI S3 6 standard This calibration procedure results in a series of files that the Audiometer software reads to keep the hardw...

Page 12: ...vant AIR Installation Manual Effective Date 12 08 2017 2 After a few seconds this message will appear Click Load 3 When the files are finished being loaded this message will appear Click YES to comple...

Page 13: ...meter Guidance and manufacturer s declaration electromagnetic emissions The Avant Audiometer is intended for use in electromagnetic environment specific below The customer or the user of the Avant Aud...

Page 14: ...P 80 to 800 MHz d 2 33 P 800 MHz to 2 5 GHz Where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation dist...

Page 15: ...ximum output power of transmitter W Separation distance according to frequency of transmitter meters 150 kHz to 80 MHz d 1 17 P 80 MHz to 800 MHz d 1 17 P 800 MHz to 2 5 GHz d 2 33 P 0 01 0 12 0 12 0...

Page 16: ...ll components with patient contact are made of bio compatible materials This device does not produce any adverse physiological effects Install the device as directed by this manual to achieve optimal...

Page 17: ...tips are single use components and should not be re used by another patient 2 It is recommended that 70 Isopropyl Alcohol should be applied to a soft clean cloth or tissue not directly on the componen...

Page 18: ...he system is two years old or less and has not been misused abused or damaged Such damage includes but is not limited to dropping exposure to excessive heat greater than 37 78 C and water liquid damag...

Reviews: