ARC-I-MARCI-2 MedRx AVANT ARC Installation Manual  

11 

Effective Date: 10-21-2016

 

 

 

 

 

8.  Wait while the InstallShield Wizard installs 

the Avant

 REM p

rogram. 

 

 

Click 

Next.

  

 

 

 
 

 

 

 

9.  When the installation is complete, Click

 

Finish.

 

 
Your AVANT ARC is USB powered.

 

Connect the USB cable from the AVANT ARC to your computer as shown below. 
 

 

 

 
Wait for the system to copy and install default Windows drivers.  
 

 

 

When this screen appears and all devices are “Ready to 
use”, click 

Close.

 

 
 

Summary of Contents for AVANT ARC

Page 1: ...INSTALLATION MANUAL www medrx usa com...

Page 2: ...alibration Files 14 EMC Precautions 15 Safety 18 Cleaning 19 Technical Information 20 Limited Warranty 23 0086 www medrx usa com 1200 Starkey Rd 105 Largo FL 33771 U S A Toll Free 888 392 1234 727 584...

Page 3: ...agnosis of otologic disorders as well as to evaluate the fitting of hearing aids and for hearing loss simulation in adults and children The software includes targets for DSL v5 0 and NAL NL2 A unique...

Page 4: ...Selected Bottom View A unique feature of the AVANT ARC is the light panel which indicates which ear is selected in the software When the unit is powered up and no ear is selected the light shines gree...

Page 5: ...re into the opening then remove the screw driver Be sure the wire is secure Repeat until all the speaker wires are secured then plug both connectors into the device Use passive speakers with 4 ohm imp...

Page 6: ...p program starts If the Setup program does not automatically start Press the Win R keys on the keyboard Type D Setup exe in the window where D is the drive letter assigned to the CD ROM drive on your...

Page 7: ...Select Accept Click Next 5 This screen sets the language and location choice Make a selection Click Next 6 This screen indicates the location of the program files The default location is recommended...

Page 8: ...Effective Date 10 21 2016 7 Installation of Program is ready to start To continue click Install To make changes click Back 8 Wait while the InstallShield Wizard Installs the AVANT Audiometer Click Ne...

Page 9: ...On the Setup screen choose Install Avant REM 2 Wait for the program to setup the InstallShield Wizard 3 This is the Welcome screen To continue click Next 4 Read the Software License Agreement This im...

Page 10: ...or most users If necessary this location can be changed To continue with the default settings click Next To change the location of the files advanced users or system administrators only click Change 6...

Page 11: ...lls the Avant REM program Click Next 9 When the installation is complete Click Finish Your AVANT ARC is USB powered Connect the USB cable from the AVANT ARC to your computer as shown below Wait for th...

Page 12: ...age 4 Click Audio Properties 5 In the Windows Sound control panel make sure the MedRx Audio Device is not set as default If it is default change this by clicking on your system audio device non MedRx...

Page 13: ...gured properly during driver installation the Audio Tab will appear like the image on the left If not use the pull down lists to adjust the settings to match the image 5 Open Audio B tab 6 When the au...

Page 14: ...a CD bearing the same serial number as your AVANT ARC device The final step before using your AVANT ARC to evaluate hearing is to load these device specific calibration files onto the computer used t...

Page 15: ...equipment can affect the Avant ARC Guidance and manufacturer s declaration electromagnetic emissions The Avant ARC is intended for use in electromagnetic environment specific below The customer or the...

Page 16: ...80 to 800 MHz d 2 33 P 800 MHz to 2 5 GHz Where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distan...

Page 17: ...wer of transmitter W Separation distance according to frequency of transmitter meters 150 kHz to 80 MHz d 1 17 P 80 MHz to 800 MHz d 1 17 P 800 MHz to 2 5 GHz d 2 33 P 0 01 0 12 0 12 0 233 0 1 0 37 0...

Page 18: ...om 0 C to 50 C All components with patient contact are made of bio compatible materials This device does not produce any adverse physiological effects Install the device as directed by this manual to...

Page 19: ...oth should never be wet just damp A mild soapy water solution is an alternative cleaning liquid 3 To ensure that cross contamination does not occur use clean cloth or sealed Alcohol swabs for each dev...

Page 20: ...xternal input is through the computer CD memory card Wave file Operator Microphone Modulation Pulse tone 0 25 0 5 s on time Warble tone 5 sinus frequency modulation repetition rate 5 Hz Patient Respon...

Page 21: ...re 20 Pa 125 45 0 250 25 5 500 11 5 750 8 0 1000 7 0 1500 6 5 2000 9 0 3000 10 0 4000 9 5 6000 15 5 8000 13 0 9000 13 0 10000 13 0 11200 13 0 12500 13 0 Speech 19 5 Calibration values Calibration val...

Page 22: ...ent should perform a subjective instrument check once a week The purpose of routine checking is to ensure as far as possible that the equipment is working properly that its calibration has not noticea...

Page 23: ...reater than 100 F and water liquid damage Repair or replacement of the system as provided under this warranty is the sole and exclusive remedy of the purchaser MedRx shall not be liable for any conseq...

Page 24: ...t Probe Microphone Left Probe Microphone Client Headphone Patient Response Button Patient Talk Back Microphone Bone Conductor Air Conduction Right Air Conduction Left USB Connection Left and Right Spe...